MODELS: SLM50 / SLM70
INSTALLATION AND OPERATING INSTRUCTIONS
CEILING/WALL VENTILATION FAN
READ AND SAVE THESE INSTRUCTIONS
GENERAL SAFETY INFORMATION
Turning angle too large
Duct shrink
1.
Make sure that the electric service supply voltage is
AC 120V, 60Hz.
DIMENSIONS
2.
Follow all local electrical and safety codes, as well as
the National Electrical Code (NEC) and the
Occupational Safety and Health Act (OSH Act).
3.
4.
Always disconnect the power source before working
on or near the ventilating fan, motor or junction box.
Too many elbows
Elbow near the body
Body
Protect the power cord from sharp edges, oil, grease,
hot surfaces, chemicals or other objects.
5.
6.
Do not kink the power cord.
Do not install the unit where ducts are configured as
shown in Fig. A.
SPECIFICATIONS
Fig. A
Air Flow
@ 0.1SP
(CFM)
7.
8.
Provide suction parts with proper ventilation.
Voltage Frequency Power
Weight
(lb.)
Model No.
Note
(V)
120
120
(Hz)
(W)
CAUTION
This unit is UL listed for use over a bathtub or shower
when installed in a GFCI protected branch circuit.
Single
Speed
Single
Speed
SLM50
SLM70
60
6.4
50
70
3.65
3.65
1.
For general ventilating use only. Do not use to
exhaust hazardous or explosive materials and vapors.
9.
These ventilating fans are intended for residential
usage only.
60
13.1
2.
3.
Not for use in cooking area. (Fig. B)
This product must be properly grounded.
Cooking area
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
Note: Design and specifications subject to change without
notice.
1.
2.
Use this unit only in the manner intended by the
manufacturer. If you have any questions, contact the
manufacturer.
OPERATION
1.
Single Speed Model: SLM50
Single speed control mode: Turn the power switch
on/off to operate ON or OFF – the LED indicator will
be green.
Before servicing or cleaning the unit, switch the
power off at service panel and lock the service
disconnecting means to prevent the power from
being switched on accidentally. When the service
disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag, to
the service panel.
2.
Single Speed Model: SLM70
Single speed control mode: Turn the power switch
on/off to operate ON or OFF – the LED indicator will
be green.
Fig. B
SUPPLIED ACCESSORIES
3.
4.
Installation work and electrical wiring must be done
by qualified person(s) in accordance with all
applicable codes and standards, including fire-rated
construction.
Part name
Appearance
Quantity
1
MAINTENANCE WARNING:
Disconnect the power source before working on the unit.
Routine maintenance must be done every year.
Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of
fuel burning equipment to prevent backdrafting.
Follow the heating equipment manufacturer’s
guideline and safety standards such as those
published by the National Fire Protection Association
(NFPA), and the American Society for Heating
Refrigeration and Air Conditioning Engineers
(ASHRAE) and local code authorities.
Grille
CAUTION:
1.
Never use gasoline, benzene, thinner or any other
such chemicals for cleaning the ventilating fan.
2.
3.
Do not allow water to enter the motor.
Do not soak resin parts in water over 60°C (140°F).
Fan
1
1
CLEANING
1.
Pull down the spring to remove the grille.
5.
6.
7.
8.
When cutting or drilling into walls or ceilings, do not
damage electrical wiring and other hidden utilities.
2.
Wash and clean the grille. (Use non-abrasive kitchen
detergent, wipe dry with a new cloth.)
Do not install this ventilating fan where air
temperature may exceed 40°C (104°F).
3.
4.
Remove dust and dirt from the ventilating fan using
a vacuum cleaner.
Housing
Duct
Ducted ventilating fans must always be vented to
the outdoors.
Using a cloth dampened with kitchen detergent,
remove any dirt from ventilating fan. Wipe dry with a
new cloth.
If this unit is to be installed over a tub or shower, it
must be marked as appropriate for the application
and be connected to a GFCI (Ground Fault Circuit
Interrupter) – protected branch circuit.
5.
Replace the grille.
1
3
Screw
(M4x12)
9.
These models are UL listed for tub and shower
enclosures.
INSTALLATIONS
Install with wood frame
10. Do not use this unit with any other solid-state
control device. Solid-state controls may cause
harmonic distortion, which can cause a motor
humming noise.
Model No.
SLM50
SLM70
11. NEVER place a switch where it can be reached from
Install Dim.
(Inch)
7.5X7.25
7.5X7.25
a tub or shower.
12. Not to be installed in a ceiling thermally insulated to
a value greater than R40. (This is required for
installation in Canada only)
1.
2.
Remove the motor plate from the housing by
removing the three screws. (Fig. C)
Remove the wiring cover from the housing by
[1]
|
Xerox Workcentre 7755 User Manual
White Rodgers Mcs600w User Manual
Wagan Solar Epower 2053 User Manual
Trane 2ttx4 User Manual
MAKITA XPH01 User Manual
KENWOOD KAT65 User Manual
HAMILTON BEACH THE SCOOP 49980 CN 02 User Manual
BLACK DECKER EM1700 User Manual
ASUS ZEN AIO PRO Z220IC User Manual
ASUS X550J User Manual