Operating Manual - English
FUJITSU Server PRIMERGY TX1330 M3
Operating Manual
May2017
Before reading this manual
For your safety
This manual contains important information for safely and correctly using this
product.
Carefully read the manual before using this product. Pay particular attention to
the accompanying manual "Safety Notes and Regulations" and ensure these
safety notes are understood before using the product. Keep this manual and the
manual "Safety Notes and Regulations" in a safe place for easy reference while
using this product.
Radio interference
This product is a "Class A" ITE (Information Technology Equipment). In a
domestic environment this product may cause radio interference, in which case
the user may be required to take appropriate measures.
VCCI-A
Aluminum electrolytic capacitors
The aluminum electrolytic capacitors used in the product's printed circuit board
assemblies and in the mouse and keyboard are limited-life components. Use of
these components beyond their operating life may result in electrolyte leakage
or depletion, potentially causing emission of foul odor or smoke.
As a guideline, in a normal office environment (25°C) operating life is not
expected to be reached within the maintenance support period (5 years).
However, operating life may be reached more quickly if, for example, the
product is used in a hot environment. The customer shall bear the cost of
replacing replaceable components which have exceeded their operating life.
Note that these are only guidelines, and do not constitute a guarantee of
trouble-free operation during the maintenance support period.
High safety use
This product has been designed and manufactured to be used in commercial
and/or industrial areas as a server.
When used as visual display workplace, it must not be placed in the direct field
of view to avoid incommoding reflections (applies only to TX server systems).
The device has not been designed or manufactured for uses which demand an
extremely high level of safety and carry a direct and serious risk of life or body
if such safety cannot be assured.
TX1330 M3
Operating Manual
These uses include control of nuclear reactions in nuclear power plants,
automatic airplane flight control, air traffic control, traffic control in mass
transport systems, medical devices for life support, and missile guidance
control in weapons systems (hereafter, "high safety use"). Customers should
not use this product for high safety use unless measures are in place for
ensuring the level of safety demanded of such use. Please consult the sales
staff of Fujitsu if intending to use this product for high safety use.
Measures against momentary voltage drop
This product may be affected by a momentary voltage drop in the power supply
caused by lightning. To prevent a momentary voltage drop, use of an AC
uninterruptible power supply is recommended.
(This notice follows the guidelines of Voltage Dip Immunity of Personal
Computer issued by JEITA, the Japan Electronics and Information Technology
Industries Association.)
Technology controlled by the Foreign Exchange and Foreign Trade
Control Law of Japan
Documents produced by Fujitsu may contain technology controlled by the
Foreign Exchange and Foreign Trade Control Law of Japan. Documents which
contain such technology should not be exported from Japan or transferred to
non-residents of Japan without first obtaining authorization in accordance with
the above law.
Harmonic Current Standards
This product conforms to harmonic current standard JIS C 61000-3-2.
Only for Japan: About SATA HDDs
The SATA version of this server supports HDDs with SATA / BC-SATA storage
interfaces. Please note that the usage and operation conditions differ
depending on the type of HDD used.
Please refer to the following internet address for further information on the
usage and operation conditions of each available type of HDD:
OperatingManual
TX1330 M3
Contents
TX1330 M3
Operating Manual
Contents
6.4.2
Configuring the SAS/SATA RAID controller
Configuring the server and installing the operating system
Configuring the server and installing the operating system
6.4.3
6.4.4
OperatingManual
TX1330 M3
Contents
TX1330 M3
Operating Manual
Contents
OperatingManual
TX1330 M3
1
Introduction
The PRIMERGY TX1330 M3 is the ideal robust and cost-efficient server for
small and medium-sized businesses (SMB) or branch offices. It offers best
Intel® Xeon® E3 performance and solid expandability thanks to hot-plug storage
drives.
The optionally redundant power supply and a choice of different RAID
controllers ensure high availability and peace of mind. Thanks to its compact
housing and extremely low operating noise the server is ideally suited for
showrooms or offices, for example under the desk. The optional support of
legacy PCI adapter cards makes the PRIMERGY TX1330 M3 optimally suited
for special solutions, such as telephone or security systems.
Furthermore, the comprehensive Fujitsu ServerView® Suite provides support
for administrators during server installation, deployment and administration.
The PRIMERGY TX1330 M3: an excellent long-term investment.
The floorstand model can be converted to a rack model using an optional
conversion kit. The rack model occupies 4 height units in the rack.
1.1
Concept and target groups for this manual
This operating manual describes how to install, set up and operate your server.
This operating manual is intended for those responsible for installing the
hardware and ensuring that the system runs smoothly. It contains all the
information you need to put your PRIMERGY TX1330 M3 into operation.
To understand the various expansion options, you will need to be familiar with
the fields of hardware and data transmission and you will require a basic
knowledge of the underlying operating system.
TX1330 M3
Operating Manual
9
Introduction
1.2
Documentation overview
More information on your PRIMERGY TX1330 M3 can be found in the following
documents:
–
–
–
"Quick Start Hardware - FUJITSU Server PRIMERGY TX1330 M3"
"ServerView Quick Start Guide"
"Safety Notes and Regulations" manual
" 安全上のご注意 " for Japan
–
"Warranty" manual
" 保証書 " for Japan
–
–
"ServerView Suite Local Service Concept - LSC" manual
"Returning used devices" manual and "Service Desk" leaflet
" サポー ト &サービス " for Japan
–
–
"FUJITSU Server PRIMERGY TX1330 M3 Upgrade and Maintenance
Manual"
"D3373 BIOS Setup Utility for FUJITSU Server PRIMERGY TX1330 M3
Reference Manual"
I
All documentation on PRIMERGY hardware and ServerView software is
available online from the Fujitsu manuals server at:
The complete PRIMERGY documentation set can also be downloaded
as a DVD ISO image at:
For Japan:
For the Japanese market:
Before using the product, please check for additional information that
may be available under the following URL:
10
OperatingManual
TX1330 M3
Introduction
Further sources of information:
–
–
–
–
–
ServerView Suite Glossary
Manual for the monitor
Documentation for the boards and drives
Operating system documentation
Information files in your operating system
1.3
Notational conventions
The following notational conventions are used in this manual:
Text in italics indicates commands or menu items.
"Quotation marks" indicate names of chapters and terms that are being
emphasized.
Ê
describes activities that must be performed in the order
shown.
V
CAUTION! pay particular attention to texts marked with this symbol.
Failure to observe this warning may endanger your life,
destroy the system or lead to the loss of data.
I
indicates additional information, notes and tips.
TX1330 M3
Operating Manual
11
Introduction
12
OperatingManual
TX1330 M3
2
Functional overview
This section provides information on the features and technical data of the
PRIMERGY TX1330 M3 server.
2.1
Features
Intel® Xeon®, Pentium® or Core™ i3 processor
The server has an Intel® Xeon®, Pentium® or Core™ i3 processor for high-
speed data processing.
Customer Self Service (CSS)
The PRIMERGY Customer Self Service (CSS) concept enables you to identify
and replace the affected component yourself in the case of certain error
scenarios.
In the CSS concept, you can replace the following components yourself in the
event of an error:
–
–
–
–
–
Hot-plug HDD/SSD modules
Hot-plug PSUs
Memory modules
System fans
Expansion cards
For information on replacing these components, see the "FUJITSU Server
PRIMERGY TX1330 M3 Upgrade and Maintenance Manual".
CSS indicators on the control panel and on the back of the PRIMERGY server
provide you with information if a CSS event arises.
In addition, CSS errors are displayed in the ServerView Operations Manager,
the server management software from Fujitsu.
In the event of errors, the ServerView Operations Manager refers you directly
to the affected component and its order information in the Illustrated Spares
catalog of the server in question. (This feature is not available for Japan.)
TX1330 M3
Operating Manual
13
Functional overview
I
Further information on the CSS concept is provided in the "PRIMERGY
ServerView Suite Local Service Concept - LSC" manual on the Fujitsu
manuals server.
For the latest information on optional products provided for the
TX1330 M3 see the configurator of the server:
For Japan:
Further information on the CSS concept is provided in the "PRIMERGY
ServerView Suite Local Service Concept - LSC" manual.
System board
The features of the system board are described in the "FUJITSU Server
PRIMERGY TX1330 M3 Upgrade and Maintenance Manual", the setup
possibilities are described in the "D3373 BIOS Setup Utility for FUJITSU Server
PRIMERGY TX1330 M3 Reference Manual".
Trusted Platform Module (TPM)
A Trusted Platform Module (TPM) for safer storage of keys can be implemented
as an option. This module enables programs from third party manufacturers to
store key information (e.g. drive encryption using Windows Bitlocker Drive
Encryption).
The TPM is activated via the BIOS system (for more information, refer to the
“D3373 BIOS Setup Utility for FUJITSU Server PRIMERGY TX1330 M3
Reference Manual").
V
CAUTION!
–
When using the TPM, note the program descriptions provided by the
third party manufacturers.
–
You must also create a backup of the TPM content. To do this, follow
the third party manufacturer's instructions. Without this backup, if the
TPM or the system board is faulty you will not be able to access your
data.
–
If a failure occurs, please inform your service about the TPM
activation before it takes any action, and be prepared to provide them
with your backup copies of the TPM content.
14
OperatingManual
TX1330 M3
Functional overview
HDDs
The server is shipped with one of the following drive cages:
–
For up to twelve 3.5-inch SAS/SATA HDDs:
Up to twelve 3.5-inch SAS/SATA HDD modules can be used in the drive
cage. Each HDD module can accommodate an SAS/SATA HDD with a
maximum height of 1 inch. The HDD modules are connected to the
SAS/SATA backplane wirelessly. This allows HDD modules to be plugged in
or pulled out easily.
I
Up to four SATA HDDs are controlled by the onboard SATA controller.
An additional SAS/SATA RAIDcontroller must be installed to control
I additional SATA HDDs or SAS HDDs.
Configurations with Eco SATA can only be mixed with BC SATA HDD
type. SAS and BC SATA drives with the same size can be mixed, but
not used in the same logical RAID volume.
–
For up to twenty four 2.5-inch SAS/SATA HDDs or 2.5-inch SATA SSD
drives:
Up to twenty four 2.5-inch HDD/SSD modules can be used in the drive cage.
Each module can accommodate SAS/SATA HDD or an SATA SSD drive with
a 2.5-inch format. The HDD/SSD modules are connected to the SAS/SATA
backplane wirelessly. This allows modules to be plugged in or pulled out
easily.
I
Up to eight SAS/SATA HDDs are controlled by the SAS/SATA RAID
I controller already installed.
Configurations with Eco SATA can only be mixed with BC SATA HDD
type. SAS and BC SATA drives with the same size can be mixed, but
not used in the same logical RAID volume.
Hybrid configurations of SATA HDD and SATA SSD modules are supported.
If the server has the corresponding RAID configuration, the HDD modules can
also be replaced during operation.
TX1330 M3
Operating Manual
15
Functional overview
Onboard SATA controller
A SATA controller is integrated on the system board; up to four SATA hard disk
drives can be connected to the controller. The LSI Embedded MegaRAID
software (SATA Software RAID) supports RAID levels 0, 1 and 10.
For more information on configuring the controller, see section "Configuring the
SAS/SATA RAID controller
The server is available with the following SAS/SATA RAID controllers for
operating the internal SAS/SATA HDDs:
–
Modular RAID 0/1 controller with "Integrated RAID" (SAS IR) for SAS3.0
RAID levels 0 and 1 are supported for internal HDD configurations.
–
Modular RAID 0/1 controller with "MegaRAID functionality"
(SAS MegaRAID) for SAS3.0
RAID levels 0, 1, 10, 1E, 5 and 50 are supported for internal HDD
configurations.
–
Modular RAID 5/6 controller with "MegaRAID functionality"
(SAS MegaRAID) for SAS3.0
RAID levels 0, 1, 10, 1E, 5, 50, 6 and 60 are supported for internal HDD
configurations. As an option, a Flash backup unit (FBU) can save the
memory content even if the power fails. Cache memory size of 1GB or 2GB
are available.
For more information on configuring the controller, see section
Further information on SAS/SATA RAID controllers is provided in the
"Modular RAID Controller Installation Guide" (on the Fujitsu manuals
server under x86 Servers - Expansion Cards - Storage Adapters - LSI RAID /
SCSI Controllers).
Further information on other SAS/SATA RAID controllers (e.g. for
operating external SAS/SATA HDDs or tape drives) is available on the
Fujitsu manuals server under x86 Servers - Expansion Cards - Storage
Adapters - LSI RAID / SCSI Controllers.
16
OperatingManual
TX1330 M3
Functional overview
Accessible drives
The server has three 5.25-inch bays that can be used in various ways:
The individual bays can be equipped with any 3.5-inch drives (height:1.6 inch).
You can install a multibay (DVD-LSD/LSP) in the top bay. You can install a
slimline DVD drive and the ServerView Local Service Display or ServerView
Local Service Panel in the multibay (DVD-LSD/LSP).
As an option for the top bay, a slimline DVD / backup drive cage is available.
I
Please note the following:
–
–
–
A DVD drive must have been installed in order to operate the server.
The accessible drives cannot be replaced during operation.
You are required to open the drive cover of system when you access
to the 5.25-inch drives.
Power supply
In its basic configuration the server has a standard PSU or a hot-plug PSU that
adjusts automatically to any mains voltage in the range 100 V - 240 V. Besides
the hot-plug PSU, a second hot-plug PSU can be installed optionally to serve
as a redundant power supply. If one PSU fails, the second PSU in the redundant
configuration ensures operation can continue uninterrupted.
Fujitsu battery unit
FJBU behaves as a modular UPS in the server. When power fail happened, the
server can operate by FJBU battery for a while.
FJBU supports hot plugging, and can be replaced during operation.
You can download the management software (FJBU management software) for
the following OS:
–
–
Windows Server 2012 R2, Windows Server 2012, Windows Server 2016
Windows Server 2008 R2 SP1, Windows Server 2008 R2 SP2
I
FJBU (Fujitsu battery unit) management software is not available in Red
Hat Enterprise Linux environment. Please use the IPMI function at Linux
environment. The TX1330 M3 will support VMware.
TX1330 M3
Operating Manual
17
Functional overview
Advanced Thermal Design
The Advanced Thermal Design option allows you to operate the system with a
wider temperature range of 5 °C to 40 °C, depending on your system and
configuration.
This option can only be ordered from the manufacturer and is
indicated by the respective logo on the identification rating
plate.
V
CAUTION
In a system that is configured with Advanced Thermal Design, only
certain components which support the respectively increased higher
operating temperature range may be installed and used. For applicable
restrictions, please refer to the official configurator tool.
High level of availability and data security
When memory data is accessed, 1-bit errors are identified in the main memory
and automatically corrected with the error correcting code (ECC) method.
ASR&R (Automatic Server Reconfiguration and Restart) restarts the system in
the event of an error and automatically "hides" the defective system
components.
The PDA (Prefailure Detection and Analysis) technology from Fujitsu analyzes
and monitors all components that are critical for system reliability.
A RAID controller supports different RAID levels and increase the availability
and data security of the system.
The hot-plug HDD modules provide additional availability.
18
OperatingManual
TX1330 M3
Functional overview
iRMC S4 with integrated management LAN connector
The iRMC S4 (integrated Remote Management Controller) is a Baseboard
Management Controller (BMC) with integrated management LAN connector
and expanded functionality that was previously only available with additional
plug-in cards. In this way, the iRMC S4 enables complete control of PRIMERGY
servers, regardless of system status, and thus particularly the control of
PRIMERGY servers that are in the "out-of-band" system status.
Major functions supported by the iRMC S4 include the following:
●
●
●
Browser access via iRMC S4´s own Web server
Secure communication (SSH, SSL)
Power Management for the managed server (depending on its system
status)
●
●
●
●
●
●
●
●
●
Power Consumption Management
Connecting virtual drives as remote storage
Text-based and graphic console bypass (Advanced Video Redirection)
Remote Storage
Command Line Interface (CLI)
Simple, interactive or script-based iRMC S4configuration
Customer Self Service (CSS)
iRMC S4´s own user management
Multi-computer, global iRMC S4 user administration using an LDAP
Directory Service
●
●
●
●
●
●
●
Automatic network configuration via DNS / DHCP
Power supply of the iRMC S4 via the system standby supply
Full-coverage alarm management
System Event Log (SEL) reading and processing
IPMI support
CIM / WS-MAN support
Internal Event Log for user login / logout auditing
TX1330 M3
Operating Manual
19
Functional overview
More information about the iRMC S4 can be found in the "iRMC S4 - integrated
Remote Management Controller" user guide (on the Fujitsu manuals server
under x86 Servers - Software - ServerView Suite - Out-Of-Band Management).
Server management
Server management is implemented using the ServerView Operations Manager
supplied and the PDA (Prefailure Detection and Analysis) technology from
Fujitsu. PDA reports the threat of a system error or overload at an early stage,
allowing preventive measures to be taken.
The ServerView Operations Manager enables the management of all
PRIMERGY servers in the network via a central console. The ServerView
Operations Manager supports the following functions:
●
●
Round-the-clock monitoring, regardless of server status
High-performance, graphical console bypass (AVR) protected by
HTTPS/SSL (128 bit)
●
●
●
●
●
●
Remote storage via USB
Remote power on
Intrusion detection in the floorstand model
Temperature monitoring of the CPU and the surrounding area
Detailed status and error reports for CPUs and main memory
Watchdog timer for Automatic Server Reconfiguration and Restart (ASR&R)
in the event that memory modules or CPUs fail
●
●
●
Power monitoring
End-of-life monitoring of fans with prompt notification before failure
Watchdog timer for monitoring the operating system with ASR&R
Further information on the ServerView Operations Manager is provided in the
associated documentation.
20
OperatingManual
TX1330 M3
Functional overview
ServerView Installation Manager
You can configure the PRIMERGY server quickly and precisely with the
ServerView Installation Manager software provided. User-guided menus are
available for installing the server operating system (for further details see
Service and support
PRIMERGY servers are easy to maintain and modular, thus enabling quick and
simple maintenance.
The handles and locks (touch points) used to exchange components are
colored green to ensure simple and immediate recognition.
In order to prevent the components from being damaged by incorrect handling
when they are being installed and removed, the areas of all components that
can be touched without damaging them are also marked green.
PRIMERGY diagnostic LEDs fitted on the system board indicate which
component (memory module, CPU, fan or expansion card) is not functioning
properly.
The Flash EPROM program supplied with the Fujitsu utilities supports a fast
BIOS update.
With the iRMC (integrated Remote Management Controller) on the system
board, the PRIMERGY TX1330 M3 server can also be maintained and serviced
remotely. This enables remote diagnosis for system analysis, remote
configuration and remote restart should the operating system or hardware fail.
TX1330 M3
Operating Manual
21
Functional overview
ServerView Remote Management
ServerView Remote Management is the remote management solution from
Fujitsu for PRIMERGY servers. ServerView Remote Management and the
relevant hardware components integrated on the system board allow remote
monitoring and maintenance as well as fast restoration of operation in the event
of errors.
Remote monitoring and maintenance avoids time-consuming and costly on-site
repairs and reduces service costs. This leads to a reduction in the total cost of
ownership and an excellent return on investment for the remote management
solution.
The administrator can access all system information and information from the
sensors such as fan speeds or voltages via the iRMC S4's Web interface (see
You can also start the text-based or graphic console bypass (Advanced Video
Redirection, AVR) and connect virtual drives as remote storage.
I
More information about the iRMC S4 can be found in the "iRMC S4 -
integrated Remote Management Controller" user guide (on the Fujitsu
manuals server under x86 Servers - Software - ServerView Suite - Out-Of-
Band Management).
22
OperatingManual
TX1330 M3
Functional overview
2.2
Server specification
This section explains the specifications for the server. The specifications for this
server are liable to be updated without any notice. Please be forewarned.
System Board
System board type
Chipset
D3373
Intel® E3-1200V6 and Intel® C236
Processor
Processor quantity and 1x Intel® Xeon®/Pentium®/ Core™ i3 processor
type
Memory Modules Configuration
Memory slots
4
Memory slot type
UDIMM (DDR4)
4 GB - 64 GB
Memory capacity
(min. - max.)
Memory protection
Memory notes
ECC
2400 MHz memory modules with 4, 8or 16 GB
TX1330 M3
Operating Manual
23
Functional overview
Interfaces
USB 2.0 connectors
USB 3.0 connectors
4 (4x external rear, no USB wake-up supported)
5 (2x external rear, 2x external front, 1x internal for
USB backup device)
Graphics (15-pin)
Serial 1 (9-pin)
1 x VGA
1 x serial RS-232-C, usable for iRMC or system or
shared
LAN / Ethernet (RJ-45) 2 x Gbit/s Ethernet
Management LAN
(RJ45)
1 x dedicated Management LAN port for iRMC S4
(10/100/1000 Mbit/s). Management LAN traffic can
be switched to shared onboard Gbit LAN port
Onboard or integrated controllers
RAID Controller Modular RAID 0/1 controller with "Integrated RAID"
(SAS IR) for SAS3.0.
RAID levels 0 and 1 are supported for internal HDD
configurations.
Modular RAID 0/1 controller with “MegaRAID
functionality” (SAS MegaRAID) for SAS3.0.
RAID levels 0, 1, 10, 1E, 5 and 50 are supported for
internal HDD configurations.
Modular RAID 5/6 controller with "MegaRAID
functionality" (SAS MegaRAID) for SAS3.0. RAID
levels 0, 1, 10, 1E, 5, 50, 6 and 60 are supported for
internal HDD configurations.
SATA Controller
A 6-port SATA controller is integrated on the system
board; up to four SATA HDDs can be connected to
the controller. The LSI Embedded MegaRAID
software (SATA Software RAID) supports RAID
levels 0, 1 and 10.
Remote Management Integrated Remote Management Controller
Controller
(iRMC S4), 256 MB DDR3-800 SRAM for video,
IPMI 2.0 compatible
Trusted Platform
Module (TPM)
Infineon V1.2 / V2.0 compliant (option)
24
OperatingManual
TX1330 M3
Functional overview
Slots
PCI-Express Gen3 x1
PCI-Express Gen3 x4
PCI-Express Gen3 x8
Slot notes
1x (up to 167 mm length)
1x (up to 167 mm length)
2x (up to 240 mm length)
In SAS configuration 1x PCI-Express occupied by
modular RAID controller.
Drive bays
Hard disk bay
configuration
4x / 8x / 12x 3.5-inch, for SAS / SATA or 8x / 16x /
24x 2.5-inch for SAS/SSD optional
Accessible drive bays 3 x 5.25/1.6-inch
Notesaccessibledrives all possible options described in relevant system
configurator
Operating Panel
Operating buttons
Status LEDs
On/off button
ID button
NMI button
Reset button
Global error indicator (orange)
ID indicator (blue)
HDD activity indicator (green)
Power-on indicator (green)
AC connected indicator (green)
CSS indicator (yellow)
Status LED at system Global error / CSS / ID indicator (orange / orange /
rear side:
blue)
LAN connection indicator (green)
LAN speed indicator (green / yellow)
TX1330 M3
Operating Manual
25
Functional overview
Dimensions / Weight
Tower (W x D x H)
Rack (W x D x H)
177 x 560 x 455 mm
483 x 495 x 174 mm (without projecting parts)
Mounting Depth Rack 543 mm
Weight
Approx. 13 - 28 kg
Weight notes
Rack mounting kit
Weight may vary depending on actual configuration
Rack mounting kit as option
Ventilation clearance
At least 200 mm on the front and rear.
Ambient conditions
Environment class 3K2
Environment class 2K2
EN 60721 / IEC 721 Part 3-3
EN 60721 / IEC 721 Part 3-2
Temperature:
Operation (3K2)
5°C ... 40°C (with ATD)
10°C ... 35°C (without ATD)
-25 °C ... 60 °C
Transport (2K2)
Humidity
10% ... 85% (non condensing)
Condensation during operation must be avoided!
Noise level (depending on the configuration)
SATA systems
SAS systems
Sound power level LWAd
(ISO 9296)
< 4.1 B (standby)
< 4.1 B (operation)
< 4.8 B (standby)
< 5.2 B (operation)
Sound pressure level at
adjacent workstation
< 23 dB (A) (standby) < 31 dB (A) (standby)
< 23 dB (A) (operation) < 34 dB (A) (operation)
L
pAm (ISO 9296)
26
OperatingManual
TX1330 M3
Functional overview
Electrical values of the PSU
Power supply
configuration
1x standard power supply or 1x hot-plug power
supply or 2x hot-plug power supplies for
redundancy.
Max. output
300 W (standard PSU)
450 W (hot-plug PSU)
Rated voltage range
100 V - 240 V
Rated frequency range 50/60 Hz
Rated current
max. 4 A / 2 A (100 V / 240 V)
Electrical values of the Fujitsu battery unit
Battery unit
1x hot-plug power supply and a Fujitsu battery unit
configuration
inserted in slot 2.
Max. output
380 W
Backup duration
Max. 2 seconds (380W), 4 minutes (280W) with
FJBU M2
Charge duration
Battery spec.
Battery life time
Input/Output voltage
Weight
4 hours to 90%,5 hours to 100%
Nickel Metal-Hydrite battery
5 years
12 V DC
1.2 kg
TX1330 M3
Operating Manual
27
Functional overview
Compliance with standards
Product safety and ergonomics
International
Europe
IEC 60950-1 2ed; am1 + am2
Safety
EN 60950-1 2ed; A1 + A2 + A11 + A12
EN 62479
Ergonomics
ISO 9241-3
EN 29241-3
EK1-ITB2000
USA / Canada
CSA-C22.2 No. 60950-1-07 2ed; am1 + am2
UL 60950-1 2ed; am1 + am2
Australia / New Zealand AS/NZS 60950-1
Taiwan
CNS 14336
GB 4943.1
IS 13252-1
China
India
Electromagnetic compatibility
International
CISPR 22 + CISPR 32
CISPR24
Europe
EN 55032 Class A
EN 55024
EN 61000-3-2
EN 61000-3-3
ETSI EN 300386
USA / Canada
47CFR part 15 Class A / ICES-003
Australia / New Zealand AS/NZS CISPR22 Class A
AS/NZS CISPR32 Class A
Taiwan
China
CNS 13438 Class A
GB 9254 / GB 17625.1
VCCI Class A / JEITA
KN 32 / KN 35
Japan
Korea
RoHS Compliance EU
EN 50581
28
OperatingManual
TX1330 M3
Functional overview
V
CAUTION!
This device meets the requirements of Class A CISPR 22/32. This device
can cause radio interference in residential areas.
TX1330 M3
Operating Manual
29
Functional overview
30
OperatingManual
TX1330 M3
3
Installation steps, overview
This chapter contains an overview of the steps necessary to install your server.
Links take you to sections where you can find more detailed information about
the respective steps:
Ê
First of all, it is essential that you familiarize yourself with the safety
Ê
Ê
Transport the server to the place where you want to set it up.
Unpack all parts, check the contents of the package for visible transport
damage and check whether the items delivered match the details on the
Ê
Ê
Make sure that all necessary manuals (see "Documentation overview" on
Components that have been ordered additionally may be delivered loose
with the server. Install these in the server as described in the supplied
documentation.
Ê
Ê
Set up the floorstand model (see section "Setting up the floorstand model"
Wire the server. Follow the instructions in sections "Connecting devices to
Ê
Ê
Connect the server to the mains (see section "Connecting the server to the
Familiarize yourself with the controls and indicators on the front and rear of
TX1330 M3
Operating Manual
31
Installation steps, overview
Ê
Configure the server and install the desired operating system and
applications. The following options are available:
–
Remote installation with the ServerView Installation Manager:
With the ServerView Suite DVD provided, you can configure the server
and install the operating system in a convenient manner.
Details on how to operate the ServerView Installation Manager, as well
as some additional information, are included in the "ServerView Suite
Installation Manager" user’s guide (on the Fujitsu manuals server under
x86 Servers - Software - ServerView Suite - Server Installation and
Deployment).
Configuration information can also be found in section "Configuring the
–
Local configuration and installation with or without the ServerView
Installation Manager (see section "Configuring the server and installing
I
You will find more information on installing the server remotely or
locally in the "ServerView Suite Installation Manager" user’s guide
(on the Fujitsu manuals server under x86 Servers - Software -
ServerView Suite - Server Installation and Deployment).
32
OperatingManual
TX1330 M3
4
Important information
I
Depending on your server or the installed options some information is not
V valid for your server.
CAUTION!
Before installing and starting up a server, please observe the safety
instructions listed in the following section. This will help you to avoid
making serious errors that could impair your health, damage the server
and endanger the data base.
4.1
Safety instructions
I
The following safety instructions are also provided in the manual "Safety
Notes and Regulations" or " 安全上のご注意 ".
This server meets the relevant safety regulations for IT equipment. If you have
any questions about whether you can install the server in the intended
environment, please contact your sales outlet or our customer service team.
●
●
●
●
The actions described in this manual shall be performed by technical
specialists. A technical specialist is a person who is trained to install the
server including hardware and software.
Repairs to the server that do not relate to CSS failures shall be performed
by service personnel. Please note that unauthorized interference with the
server will void the warranty and exempt the manufacturer from all liability.
Any failure to observe the guidelines in this manual, and any improper
repairs could expose the user to risks (electric shock, energy hazards, fire
hazards) or damage the equipment.
Only valid for non hot-plug components
Before installing/removing internal components to/from the server, turn off
the server, all peripheral devices, and any other connected devices. Also
unplug all power cords from the power outlet. Failure to do so can cause
electric shock or damage.
Before starting up
●
During installation and before operating the server, observe the instructions
on environmental conditions for your server.
TX1330 M3
Operating Manual
33
Important information
●
If the server is brought in from a cold environment, condensation may form
both inside and on the outside of the server.
Wait until the server has acclimatized to room temperature and is absolutely
dry before starting it up. Material damage may be caused to the server if this
requirement is not observed.
●
Only transport the server in its original packaging or in packaging that
protects it from impacts and jolts.
In Japan and APAC, transporting the server in its original packaging does
not apply.
Installation and operation
●
This server should not be operated in ambient temperatures above 35 °C.
For servers with Advanced Thermal Design the ambient temperature can
increase to 40 °C or 45 °C.
●
If the server is integrated into an installation that draws power from an
industrial power supply network with an IEC309 connector, the power
supply's fuse protection must comply with the requirements for non-
industrial power supply networks for type A connectors.
●
●
The server automatically adjusts itself to a mains voltage, see the type label
of your server. Ensure that the local mains voltage lies within these limits.
This server must only be connected to properly grounded power outlets or
connected to the grounded rack internal power distribution server with
tested and approved power cords.
●
●
●
Ensure that the server is connected to a properly grounded power outlet
close to the server.
Ensure that the power sockets on the server and the properly grounded
power outlets are easily accessible.
The On/Off button or the main power switch (if present) does not isolate the
server from the mains power supply. In case of repair or servicing disconnect
the server completely from the mains power supply, unplug all power plugs
from the properly grounded power outlets.
●
Always connect the server and the attached peripheral devices to the same
power circuit. Otherwise you run the risk of losing data if, for example, the
server is still running but a peripheral device (e.g. memory subsystem) fails
during a power outage.
34
OperatingManual
TX1330 M3
Important information
●
The adequately shielded data cables must be used.
All data and signal cables must have sufficient shielding. The use of cable
type S/FTP Cat5 or higher is recommended.
Use of unshielded or badly shielded cables may lead to increased emission
of interference and/or reduced fault-tolerance of the device.
●
●
Ethernet cabling has to comply with EN 50173 and EN 50174-1/2 standards
or ISO/IEC 11801 standard respectively. The minimum requirement is a
Category 5 shielded cable for 10/100 Ethernet, or a Category 5e cable for
Gigabit Ethernet.
Route the cables in such a way that they do not create a potential hazard
(make sure no-one can trip over them) and that they cannot be damaged.
When connecting the server, refer to the relevant instructions in this manual.
●
●
●
Never connect or disconnect data transmission lines during a storm (risk of
lightning hazard).
Make sure that no objects (e.g. jewelry, paperclips etc.) or liquids can get
inside the server (risk of electric shock, short circuit).
In emergencies (e.g. damaged casing, controls or cables, penetration of
liquids or foreign bodies), contact the server administrator or your customer
service team. Only disconnect the server from the mains power supply if
there is no risk of harming yourself.
●
●
Proper operation of the server (in accordance with IEC 60950-1 resp.
EN 60950-1) is only ensured if the server is completely assembled and the
rear covers for the installation slots have been fitted (electric shock, cooling,
fire protection, interference suppression).
Only install server expansions that satisfy the requirements and rules
governing safety and electromagnetic compatibility and those relating to
telecommunication terminals. If you install other expansions, they may
damage the server or violate the safety regulations. Information on which
server expansions are approved for installation can be obtained from our
customer service center or your sales outlet.
●
●
The components marked with a warning notice (e.g. lightning symbol) may
only be opened, removed or exchanged by authorized, qualified personnel.
Exception: CSS components can be replaced.
The warranty is void if the server is damaged during installation or
replacement of server expansions.
TX1330 M3
Operating Manual
35
Important information
●
●
Only set screen resolutions and refresh rates that are specified in the
operating manual for the monitor. Otherwise, you may damage your monitor.
If you are in any doubt, contact your sales outlet or customer service center.
Only valid for non hot-plug components
Before installing/removing internal components to/from the server, turn off
the server, all peripheral devices, and any other connected devices. Also
unplug all power cords from the power outlet. Failure to do so can cause
electric shock or damage.
Internal devices remain hot after shutdown. Wait for a while after shutdown
before installing or removing internal options.
●
●
Do not damage or modify internal cables or internal devices. Doing so may
cause a server failure, fire, or electric shock and will void the warranty and
exempt the manufacturer from all liability.
The circuit boards and soldered parts of internal options are exposed and
can be damaged by static electricity. To ensure reliable protection, you must
wear an earthing band on your wrist when working with this type of module
and connect it to an unpainted, conducting metal part of the server.
●
●
Do not touch the circuitry on boards or soldered parts. Hold the metallic
areas or the edges of the circuit boards.
Install the screw removed during installation/detaching internal options in
former position. To use a screw of the different kind can cause a breakdown
of equipment.
●
The procedure of installation on this notes might change depending on a
configuration of option.
Batteries
●
Incorrect replacement of batteries may lead to a risk of explosion. The
batteries may only be replaced with identical batteries or with a type
recommended by the manufacturer.
●
Do not throw batteries into the trash can.
Batteries must be disposed of in accordance with local regulations
concerning special waste.
●
Make sure that you insert the battery the right way round.
36
OperatingManual
TX1330 M3
Important information
●
●
●
The battery used in this server may present a fire or chemical burn hazard if
mistreated. Do not disassemble, heat about 100 °C (212F), or incinerate the
battery.
Replace the lithium battery on the system board in accordance with the
instructions in the corresponding Upgrade and Maintenance Manual,
chapter "System board and components" > "CMOS battery".
All batteries containing pollutants are marked with a symbol (a crossed-out
garbage can). In addition, the marking is provided with the chemical symbol
of the heavy metal decisive for the classification as a pollutant:
Cd Cadmium
Hg Mercury
Pb Lead
Working with optical disk drives and media
When working with optical disk drives, these instructions must be followed.
V
CAUTION!
●
●
Only use CDs/DVDs/BDs that are in perfect condition, in order to
prevent data loss, equipment damage and injury.
Check each CD/DVD/BD for damage, cracks, breakages etc. before
inserting it in the drive.
Note that any additional labels applied may change the mechanical
properties of a CD/DVD/BD and cause imbalance and vibrations.
Damaged and imbalanced CDs/DVDs/BDs can break at high drive
speeds (data loss).
Under certain circumstances, sharp CD/DVD/BD fragments can
pierce the cover of the optical disk drive (equipment damage) and can
fly out of the drive (danger of injury, particularly to uncovered body
parts such as the face or neck).
●
High humidity and airborne dust levels are to be avoided. Electric
shocks and/or server failures may be caused by liquids such as
water, or metallic items, such as paper clips, entering a drive.
●
●
Shocks and vibrations are also to be avoided.
Do not insert any objects other than the specified CDs/DVDs/BDs.
TX1330 M3
Operating Manual
37
Important information
●
Do not pull on, press hard, or otherwise handle the CD/DVD/BD tray
roughly.
●
●
●
Do not disassemble the optical disk drive.
Before use, clean the optical disk tray using a soft, dry cloth.
As a precaution, remove disks from the optical disk drive when the
drive is not to be used for a long time. Keep the optical disk tray
closed to prevent foreign matter, such as dust, from entering the
optical disk drive.
●
●
Hold CDs/DVDs/BDs by their edges to avoid contact with the disk
surface.
Do not contaminate the CD/DVD/BD surface with fingerprints, oil,
dust, etc. If dirty, clean with a soft, dry cloth, wiping from the center to
the edge. Do not use benzene, thinners, water, record sprays,
antistatic agents, or silicone-impregnated cloth.
●
●
●
●
●
Be careful not to damage the CD/DVD/BD surface.
Keep the CDs/DVDs/BDs away from heat sources.
Do not bend or place heavy objects on CDs/DVDs/BDs.
Do not write with ballpoint pen or pencil on the label (printed) side.
Do not attach stickers or similar to the label side. Doing so may cause
rotational eccentricity and abnormal vibrations.
●
When a CD/DVD/BD is moved from a cold place to a warm place,
moisture condensation on the CD/DVD/BD surface can cause data
read errors. In this case, wipe the CD/DVD/BD with a soft, dry cloth
then let it air dry. Do not dry the CD/DVD/BD using devices such as a
hair dryer.
●
●
To avoid dust, damage, and deformation, keep the CD/DVD/BD in its
case whenever it is not in use.
Do not store CDs/DVDs/BDs at high temperatures. Areas exposed to
prolonged direct sunlight or near heating appliances are to be
avoided.
I
You can prevent damage from the optical disk drive and the
CDs/DVDs/BDs, as well as premature wear of the disks, by observing
the following suggestions:
38
OperatingManual
TX1330 M3
Important information
–
Only insert disks in the drive when needed and remove them after
use.
–
–
Store the disks in suitable sleeves.
Protect the disks from exposure to heat and direct sunlight.
Laser information
The optical disk drive complies with IEC 60825-1 laser class 1.
V
CAUTION!
The optical disk drive contains a light-emitting diode (LED), which under
certain circumstances produces a laser beam stronger than laser
class 1. Looking directly at this beam is dangerous.
Never remove parts of the optical disk drive casing!
Modules with Electrostatic-Sensitive Devices (ESD modules)
Modules with electrostatic-sensitive devices are identified by the following
sticker:
Figure 1: ESD label
I
The ESD label can be different.
When you handle ESD modules, you must always observe the following points:
●
Switch off the server and remove the power plugs from the power outlets
before installing or removing ESD modules.
●
The circuit boards and soldered parts of internal options are exposed and
can be damaged by static electricity. To ensure reliable protection, you must
wear an earthing band on your wrist when working with ESD modules and
connect it to an unpainted, conducting metal part of the server.
●
Any devices or tools that are used must be free of electrostatic charge.
TX1330 M3
Operating Manual
39
Important information
●
●
Wear a suitable grounding cable that connects you to the external chassis
of the server.
Always hold ESD modules at the edges or at the points marked green (touch
points).
●
●
Do not touch any connectors or conduction paths on an ESD module.
Place all the components on a pad which is free of electrostatic charge.
I
For a detailed description of how to handle ESD modules, see the
relevant European or international standards (EN 61340-5-1,
ANSI/ESD S20.20).
Transporting the server
V
CAUTION!
Only transport the server in its original packaging or in packaging that
protects it from impacts and jolts.
In Japan and APAC, transporting the server in its original packaging does
not apply.
Do not unpack the server until it is at its installation location.
If you need to lift or transport the server, ask other people to help you.
Never lift or carry the server by the handles or the Quick Release Levers
(QRLs) on the front panel.
Notes on installing the server in the rack
V
CAUTION!
●
For safety reasons, at least 2 people are required to install the
server in the rack because of its weight and size.
(For the reader in Japan, please refer to " 安全上のご注意 ".)
●
●
Never lift the server into the rack using the QRLs (Quick Release
Levers) on the front panel.
When connecting and disconnecting cables, observe the relevant
instructions in the "Important Information" chapter of the technical
manual for the corresponding rack. The technical manual is supplied
with the corresponding rack.
●
When installing the rack, make sure that the anti-tilt mechanism is
correctly fitted.
40
OperatingManual
TX1330 M3
Important information
●
Do not extend more than one server out of the rack simultaneously
even if the tilt protection is in place. If several servers are
simultaneously extended from the rack, there is a risk that the rack
could tip over. See the safety information of the rack and the warning
label.
●
●
If the server/rack is intended for permanent connection to the mains
only an authorized specialist (electrician) is allowed to work.
Please follow the regulation of each country.
If the server is integrated into an installation that draws power from an
industrial power supply network with an IEC309 type connector, the
power supply's fuse protection must comply with the requirements for
non-industrial power supply networks for the type A connector.
Other important information
●
During cleaning, observe the instructions in the corresponding Operating
Manual chapter "Starting up and operation" > "Cleaning the server".
●
Keep all manuals close to the server. All documentation must be included if
the equipment is passed on to a third party.
4.2
ENERGY STAR
Products that have been certified compliant with ENERGY STAR
and labelled are in full compliance with the specification at
shipping. Note that energy consumption can be affected by
software that is installed or any changes that are made to the
hardware configuration or BIOS or energy options subsequently.
In such cases, the properties guaranteed by ENERGY STAR can
no longer be assured.
The "ServerView Operations Manager" user guide contains
instructions for reading out measurement values, including those
relating to current energy consumption and air temperatures.
Either the Performance Monitor or the Task Manager can be
used to read out CPU utilization levels.
TX1330 M3
Operating Manual
41
Important information
4.3
CE conformity
:The system complies with the requirements of European
Regulations. Find the CE declaration on certificate portal:
To open the CE declaration applicable for your system, proceed
as follows:
Ê
Ê
Ê
Ê
Select Industry Standard Servers.
Select your model, e.g. Rack server.
Select your system, e.g. PRIMERGY RX2530 M1.
Select CE Cert <your system>.
V
CAUTION!
This is a Class A product. In a domestic environment this
product may cause RF interference, in which case the
user may be required to take adequate measures.
42
OperatingManual
TX1330 M3
Important information
4.4
FCC Class A Compliance Statement
If there is an FCC statement on the device, it applies to the products covered in
this manual, unless otherwise specified herein. The statement for other
products will appear in the accompanying documentation.
NOTE:
This equipment has been tested and found to comply with the limits for a
"Class A" digital device, pursuant to Part 15 of the FCC rules and meets all
requirements of the Canadian Interference-Causing Equipment Standard
ICES-003 for digital apparatus. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in strict accordance with the instructions, may cause harmful
interference to radio communications. However, there is no warranty that
interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures:
●
●
●
Reorient or relocate the receiving antenna.
Increase the separation between equipment and the receiver.
Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected.
●
Consult the dealer or an experienced radio/TV technician for help.
Fujitsu is not responsible for any radio or television interference caused by
unauthorized modifications of this equipment or the substitution or attachment
of connecting cables and equipment other than those specified by Fujitsu. The
correction of interferences caused by such unauthorized modification,
substitution or attachment will be the responsibility of the user.
The use of shielded I/O cables is required when connecting this equipment to
any and all optional peripheral or host devices. Failure to do so may violate FCC
and ICES rules.
TX1330 M3
Operating Manual
43
Important information
4.5
Environmental protection
Environmentally-friendly product design and development
This product has been designed in accordance with the Fujitsu standard for
"environmentally friendly product design and development". This means that
key factors such as durability, selection and labeling of materials, emissions,
packaging, ease of dismantling and recycling have been taken into account.
This saves resources and thus reduces the harm done to the environment.
Further information can be found at:
For the reader in Japan:
Energy-saving information
Devices that do not need to be constantly switched on should be switched off
until they are needed as well as during long breaks and after completion of work.
Packaging information
This packaging information does not apply in Japan and APAC.
Do not throw away the packaging. You may need it later for transporting the
server. If possible, the equipment should only be transported in its original
packaging.
Information on handling consumables
Please dispose of printer consumables and batteries in accordance with the
applicable national regulations.
In accordance with EU directives, batteries must not be disposed of with
unsorted domestic waste. They can be returned free of charge to the
manufacturer, dealer or an authorized agent for recycling or disposal.
All batteries containing pollutants are marked with a symbol (a crossed-out
garbage can). They are also marked with the chemical symbol for the heavy
metal that causes them to be categorized as containing pollutants:
Cd Cadmium
Hg Mercury
Pb Lead
44
OperatingManual
TX1330 M3
Important information
Labels on plastic casing parts
Please avoid sticking your own labels on plastic parts wherever possible, since
this makes it difficult to recycle them.
Returns, recycling and disposal
Please handle returns, recycling and disposal in accordance with local
regulations.
The device must not be disposed of with domestic waste. This
device is labeled in compliance with European directive
2012/19/EU on waste electrical and electronic equipment (WEEE).
This directive sets the framework for returning and recycling used
equipment and is valid across the EU. When returning your used
device, please use the return and collection systems available to
you. Further information can be found at:
Details regarding the return and recycling of devices and consumables within
Europe can also be found in the "Returning used devices" manual, via your local
Fujitsu branch, or at:
TX1330 M3
Operating Manual
45
Important information
4.6
Notes on installing the server in the rack
V
CAUTION!
●
For safety reasons, at least two people are required to install the
server in the rack because of its weight and size.
(For Japan, please refer to " 安全上のご注意 ".)
●
●
Never lift the server into the rack using the QRLs (Quick Release
Levers) on the front panel.
When connecting and disconnecting cables, observe the relevant
instructions in the chapter "Important information" of the technical
manual for the corresponding rack. The technical manual is supplied
with the corresponding rack.
●
●
When installing the rack, make sure that the anti-tilt mechanism is
correctly fitted.
Do not extend more than one unit out of the rack simultaneously even
if the tilt protection is in place. If several units are simultaneously
extended from the rack, there is a risk that the rack could tip over. See
the safety information of the rack and the warning label.
●
●
Not valid for Japan:
The rack must be connected to the power supply by an authorized
specialist (electrician).
If the server is integrated into an installation that draws power from an
industrial power supply network with an IEC309 type connector, the
power supply's fuse protection must comply with the requirements for
non-industrial power supply networks for the type A connector.
46
OperatingManual
TX1330 M3
5
Hardware installation
V
CAUTION!
●
Follow the safety instructions in the chapter "Important information"
●
Do not expose the server to extreme environmental conditions (see
"Ambient conditions" on page 26). Protect the server from dust,
humidity and heat.
●
Make sure that the server is acclimatized for the time indicated in this
table before putting it into operation.
Temperature difference (°C) Minimum acclimatization time
(hours)
5
3
5
10
15
7
20
8
25
30
9
10
Table 1: Acclimatization time
to the difference between the operating environment temperature and
the temperature to which the server was exposed previously (outside,
transport or storage temperature).
TX1330 M3
Operating Manual
47
Hardware installation
5.1
Unpacking the server
V
CAUTION!
The server must always be lifted or carried by at least two people.
For Japan:
Please refer to " 安全上のご注意 ".
Do not unpack the server until it is at its installation location.
Ê
Ê
Transport the server to the place where you want to set it up.
Unpack all individual parts.
Keep the original packaging in case you want to transport the server again
(does not apply to Japan).
Ê
Ê
Check the delivery for any damage during transport.
Check whether the items delivered match the details on the delivery note.
The product name and serial number of the product can be found on the ID card
Ê
Notify your supplier immediately should you discover that the items
delivered do not correspond to the delivery note.
48
OperatingManual
TX1330 M3
Hardware installation
5.2
Setting up the floorstand model
I
If you are not installing a PRIMERGY TX1330 M3 floorstand model, skip
this section and continue reading at section "Installing/removing the
Ê
Ê
Ê
Transport the server to the place where you want to set it up.
Set up the server.
V
CAUTION!
–
–
The device must be protected from direct sunlight.
The required minimum distances for operation and maintenance
areas must be adhered to.
–
The server must be accessible at the rear for connection to other
devices (e.g. memory subsystem).
–
–
The mains plug must be accessible easily and safely.
There must be a clearance of at least 200 mm in front of and
behind the server to ensure adequate ventilation of the
subsystem.
Ê
Ê
Wire the server. Follow the instructions in sections "Connecting devices to
Connect the server to the mains (see section "Connecting the server to the
TX1330 M3
Operating Manual
49
Hardware installation
5.3
Installing/removing the server in/from the
rack
V
CAUTION!
●
Please observe the safety information and notes on rack mounting in
●
●
At least two people are needed to install / remove the server in the
rack. (For Japan, please refer to " 安全上のご注意 ".)
Do not extend more than one unit out of the rack simultaneously even
if the tilt protection is in place. If several units are simultaneously
extended out of the rack, there is a risk that the rack could tip over.
Fujitsu rack systems
The rack systems from Fujitsu support the installation of PRIMERGY servers:
–
–
–
–
–
PRIMECENTER rack
PRIMECENTER M1 rack
DataCenter rack
19-inch standard rack (for Japan)
19-inch slim rack (for Japan)
I
For information on mounting the server in the rack please refer to the
Mounting Instructions provided with the Rack Mounting Kit. Further
information you find in the manual of your rack system.
I For Japan, please refer also to the "Rack system structure guide.
Online documentation for rack installation can be found on:
For Japan:
To accommodate the ventilation concept and ensure proper ventilation, any
unused areas in the rack must be sealed using dummy covers.
The power is supplied via the multiple socket outlets fitted in the rack (not valid
for Japan).
The main features of Fujitsu rack systems are as follows:
–
rail systems that can be mounted without tools
OperatingManual
50
TX1330 M3
Hardware installation
–
support systems having a linear alignment feature to ensure that they can
be adjusted to different rack depths
Asymmetrical PRIMECENTER Rack and DataCenter Rack provide an
enhanced cable management in the lateral rack area.
3rd party racks
I
Installation in most current rack systems from other manufacturers
(3rd party racks) is also supported. For details please contact your sales
representative.
TX1330 M3
Operating Manual
51
Hardware installation
5.4
Connecting devices to the server
The connectors for external devices are on the front and rear of the server. The
additional connectors available on your server depend on the expansion cards
installed. For further information refer to the “FUJITSU Server PRIMERGY
TX1330 M3 Upgrade and Maintenance Manual”. The standard connectors are
indicated by symbols and color coding:
ቢ
ባ
ቤ
ቦ
ቧ
ብ
Figure 2: Connector panel on the rear side
1 Management LAN connector, for iRMC S4 server management function
2 Shared LAN connector (LAN1)
3 Standard LAN connector (LAN2)
4 6 USB connectors: 4x USB 2.0 (black); 2x USB3.0 (blue)
5 Video connector (blue)
6 Serial connector COM1 (turquoise)
I
Some of the devices that can be connected may require special drivers
(see the documentation for the connected device).
Ê
Connect the data cables to the server and peripherals.
52
OperatingManual
TX1330 M3
Hardware installation
Two additional USB connectors (2x USB 3.0) are located on the front of the
Connecting the monitor
Ê
Connect the monitor to the video connector of the server (see figure 2 on
Ê
Connect the power cable of the monitor to a grounded mains outlet of the in-
house mains and/or to the mains socket strip of the rack.
V
CAUTION!
The rated current for the monitor is indicated on the technical data label
on the monitor or in the operating manual for the monitor.
5.5
Connecting the server to the mains
The server is equipped with an integrated PSU.
V
CAUTION!
The server is automatically set to a mains voltage in the range 100 V -
240 V. You may only operate the server if its rated voltage range
corresponds to the local mains voltage.
Ê
Ê
Connect the power cord to the server PSU.
Connect the mains plug to a grounded mains outlet in the in-house power
supply network or a power outlet of the socket strip in the rack (see Technical
Manual for rack).
TX1330 M3
Operating Manual
53
Hardware installation
5.5.1 Using cable ties (standard PSU)
You can secure the power cable using a cable tie to ensure that the insulated
connector cannot be disconnected from the server accidentally. The cable tie is
included in the accessories pack that is delivered together with the server.
ባ
ቢ
Figure 3: Using cable ties (standard PSU)
Ê
Ê
Thread the cable tie through the eye (1).
Pull the cable tie tight to secure the power cable.
The insulated connector cannot now be disconnected from the server
accidentally.
You can loosen the cable tie by opening the small locking lever (2).
54
OperatingManual
TX1330 M3
Hardware installation
5.5.2 Using cable ties (hot-plug PSU)
You can secure the power cable using a cable tie to ensure that the insulated
connector cannot be disconnected from the server accidentally. The cable tie is
included in the accessories pack that is delivered together with the server.
ባ
ቢ
Figure 4: Using cable ties (hot-plug PSU)
Ê
Ê
Thread the cable tie through the eye (1).
Pull the cable tie tight to secure the power cable.
The insulated connector cannot now be disconnected from the server
accidentally.
You can loosen the cable tie by opening the small locking lever (2).
TX1330 M3
Operating Manual
55
Hardware installation
5.6
Notes on connecting/disconnecting cables
V
CAUTION!
Always read the documentation supplied with the device you wish to
connect.
Never connect, or disconnect cables during a thunderstorm.
Never pull on a cable when disconnecting it. Always take hold of the
cable by the plug.
Follow the sequence described below to connect or disconnect external
devices to or from the server:
Be sure to wait for 10 seconds or more after shutdown before turning the
server on.
Connecting cables
Ê
Ê
Ê
Ê
Ê
Turn off all power and equipment switches.
Disconnect all power plugs from the properly grounded power outlets.
Connect all cables to the server and peripherals.
Plug all data communication cables into the utility sockets.
Plug all power cords into the properly grounded power outlets.
Disconnecting cables
Ê
Ê
Ê
Ê
Turn off all power and equipment switches.
Disconnect all power plugs from the properly grounded power outlets.
Unplug all data communication cables from the utility sockets.
Disconnect the relevant cables from the server and all the peripherals.
I
For connecting or disconnecting LAN cables, the server does not need
to be powered off. To avoid loss of data teaming function has to be
enabled.
56
OperatingManual
TX1330 M3
Hardware installation
Information for ensuring electromagnetic compatibility
All data and signal cables must have sufficient shielding. The use of cable type
S/FTP Cat5 or higher is recommended.
Use of unshielded or badly shielded cables may lead to increased emission of
interference and/or reduced fault-tolerance of the device.
TX1330 M3
Operating Manual
57
Hardware installation
58
OperatingManual
TX1330 M3
6
Starting up and operation
V
CAUTION!
Follow the safety instructions in chapter "Important information" on
6.1
Access to the drives (floorstand model)
6.1.1 Enabling access to the accessible drives
Figure 5: Removing the drive cover and placing it on the HDD cover
Ê
Ê
Ê
Ê
Unlock the server (1).
Remove the drive cover (2).
Place the accessible drive bay as shown (3).
Push down the drive cover in the direction of the arrow (4).
TX1330 M3
Operating Manual
59
Starting up and operation
I
Please note the following when operating with tape drives:
If the system is programmed to eject the media automatically, the
accessible drives must not be obstructed.
The drive cover is replaced and the server locked in the reverse order.
60
OperatingManual
TX1330 M3
Starting up and operation
6.2
Control elements and indicators
6.2.1 Front of the server
Figure 7: Front panel
1
2
3
4
5
2x USB 3.0
6
7
8
9
Global Error indicator
Reset button
HDD activity indicator
NMI button
On/Off button / Power-on indicator
AC-connected indicator
ID button / ID indicator
CSS indicator
62
OperatingManual
TX1330 M3
Starting up and operation
6.2.1.1 Control elements
Lock (only floorstand model)
The server can be locked to prevent access to the drives.
Pos.
Label
Button
Function
Reboots the system.
Press the reset button with a straightened end
of a paper clip.
1
RESET Reset button
V
CAUTION!
Risk of data loss!
Used to troubleshoot software and device driver
errors.
Press the NMI button with a straightened end of
a paper clip.
2
NMI
ID
NMI button
V
CAUTION!
Use this button only if directed to do so
by qualified certified maintenance
personnel!
Highlights the ID indicator on the front panel and
the rear panel for easy server identification.
3
4
ID button
Used to switch the server on or off.
I
If the system is running an ACPI-
compliant operating system, pressing
the On/Off button will perform a graceful
shutdown.
On/Off button
TX1330 M3
Operating Manual
63
Starting up and operation
6.2.1.2 Indicators on the control panel
Pos.
Label
Indicator
Status
Description
The server has been highlighted
using ServerView Operations
Manager, iRMC web frontend or the
ID button on the front panel for easy
identification.
ID indicator,
see also
"iRMC-
blue on
1
ID
related
signals" on
The server has been highlighted for
easy identification using the iRMC
(AVR) with disabled local VGA
output.
blue
flashing
No critical event detected (CSS
component).
off
CSS
indicator
Prefailure event detected (CSS
component).
2
[CSS]
orange on
orange
flashing
CSS component failure detected.
No critical event detected (non CSS
component).
off
Prefailure event detected (non CSS
component).
orange on
Global Error
indicator,
see also
"iRMC-
Non CSS component failure
detected.
Possible causes:
!
3
related
signals" on
–
System is out of the temperature
specified range
Defective sensor
CPU error
Error detected by server
management software
orange
flashing
–
–
–
HDD/SSD
activity
indicator
green
flashing
4
Data access in progress.
64
OperatingManual
TX1330 M3
Starting up and operation
Pos.
Label
Indicator
Status
Description
The server is switched off.
off
–
The server has been switched on
but Power Cycle Delay settings
delay it from turning on for a
specified time.
green on
Power-on
indicator
5
–
The server is switched on and
operating normally.
green
flashing
slowly
The BMC firmware is starting up
after the server has been connected
to the mains.
–
The server is switched off and
connected to the mains
(standby mode).
–
The server has been switched on
but Power Cycle Delay settings
delay it from turning on for a
specified time.
green on
AC
connected
indicator
I
After connecting the server to
the mains, it will take about
60 seconds until the server
will enter standby mode and
can be switched on.
6
–
–
The server is switched off and
not connected to the mains.
The server is switched on and
operating normally.
off
iRMC-related status signals
Global error
ID indicator
Description
indicator
A remote connection has been
blue flashing
off
established. Local VGA output has been
disabled during the remote session.
TX1330 M3
Operating Manual
65
Starting up and operation
Global error
ID indicator
Description
indicator
An emergency flash of the iRMC firmware
is in progress.
I
For further information on the
emergency flash of the iRMC
firmware, refer to the "FUJITSU
Server PRIMERGY TX1330 M3
Upgrade and Maintenance
Manual".
blue flashing
orange flashing
66
OperatingManual
TX1330 M3
Starting up and operation
6.2.1.3 ID card
Figure 8: ID card
You can pull out the ID card as far as it will go and push it back again.
The ID card contains various system information, such as the product name,
serial number, order number, MAC addresses and DNS name (in the Japanese
market, only the product name and the serial number).
TX1330 M3
Operating Manual
67
Starting up and operation
6.2.1.4 Indicators on the drives
Optical drive activity indicator
Lights up green when the storage medium is being accessed.
HDD indicators
ቢ
ባ
Figure 9: Indicators on the 3.5 inch HDD modules
ቢ
ባ
Figure 10: Indicators on the 2.5 inch HDD modules
68
OperatingManual
TX1330 M3
Starting up and operation
Pos.
Label
Indicator
Status
Description
off
No HDD/SSD error detected.
An HDD/SSD error has been
detected.
Possible causes:
–
–
–
The drive is defective and needs
replacing.
A RAID rebuild process has
failed.
The HDD/SSD module has not
been inserted correctly.
orange on
Error
indicator
!
1
HDD/SSD RAID rebuild is in
progress. Data is being restored
after replacing a drive that has been
combined into a RAID array.
orange
flashing
slowly
off
The HDD/SSD is inactive.
Access
2
indicator
green on The HDD/SSD being accessed
TX1330 M3
Operating Manual
69
Starting up and operation
6.2.2 Rear of server
6.2.2.1 Indicators on the connector panel
CSS, Global Error and ID indicators
ቢ
Figure 11: Indicators on the connector panel: CSS, Global Error and ID indicators
1
CSS, Global Error and ID indicators (orange, orange and blue)
70
OperatingManual
TX1330 M3
Starting up and operation
Pos.
Label
Indicator
Status
Description
The server has been highlighted
using ServerView Operations
Manager, iRMC web frontend or the
ID button on the front panel for easy
identification.
ID indicator,
see also
"iRMC-
blue on
ID
related
signals" on
The server has been highlighted for
easy identification using the iRMC
(AVR) with disabled local VGA
output.
blue
flashing
No critical event detected (CSS
component).
off
CSS
indicator
Prefailure event detected (CSS
component).
[CSS]
orange on
orange
flashing
CSS component failure detected.
1
No critical event detected (non CSS
component).
off
Prefailure event detected (non CSS
component).
orange on
Global Error
indicator,
see also
"iRMC-
Non CSS component failure
detected.
Possible causes:
!
related
signals" on
–
System is out of the specified
temperature range
Defective sensor
CPU error
Error detected by server
management software
orange
flashing
–
–
–
I
Note on CSS and Global Error indicators on the I/O panel
If CSS and Global Error indicators are located in the same place on your
server’s I/O panel, please also check the indicators on the front panel to
I determine if a CSS or Global Error event has been detected.
For further details on detected errors, refer to the System Event Log
(SEL) or use the ServerView Operations Manager or iRMC S4 web
interface.
TX1330 M3
Operating Manual
71
Starting up and operation
iRMC-related status signals
Global error
ID indicator
Description
indicator
A remote connection has been
blue flashing
blue flashing
off
established. Local VGA output has been
disabled during the remote session.
An emergency flash of the iRMC firmware
is in progress.
I
For further information on the
emergency flash of the iRMC
firmware, refer to the "FUJITSU
Server PRIMERGY TX1330 M3
Upgrade and Maintenance
Manual".
orange flashing
72
OperatingManual
TX1330 M3
Starting up and operation
LAN indicators
ቢ ባ
ቢ ባ ቢ ባ
Figure 12: Indicators on the connector panel: LAN indicators
Pos. Indicator
Status
green on
off
Description
A LAN connection has been established.
LAN is not connected.
LAN
1
2
link/transfer
indicator
green flashing LAN data transfer is in progress
yellow on
green on
off
Data traffic at a transfer rate of 1 Gbit/s
Data traffic at a transfer rate of 100 Mbit/s
Data traffic at a transfer rate of 10 Mbit/s.
LAN speed
indicator
I
Depending on the settings in the BIOS, the shared LAN connector may
also be used as a Management LAN connector. You will find further
information in the "D3373 BIOS Setup Utility for FUJITSU Server
PRIMERGY TX1330 M3 Reference Manual".
TX1330 M3
Operating Manual
73
Starting up and operation
Indicator of hot-plug PSU
Figure 13: Indicator on hot-plug PSU
Pos. Indicator
Status
Description
green flashing The server is switched off, but mains
voltage is present (standby mode).
green on
The server is switched on and operating
properly.
orange
flashing
An overload has been detected. The PSU
is still running, but failure might be
imminent.
PSU status
indicator
1
orange on
An PSU failure has been detected.
Possible causes:
–
–
–
Over/under voltage
Overheating
Fan failure
74
OperatingManual
TX1330 M3
Starting up and operation
Indicator of Fujitsu battery unit (FJBU M2)
Figure 14: Indicator on Fujitsu battery unit
Pos. Indicator
Status
Description
green flashing The battery unit is charging.
green flashing The battery unit is discharging.
slowly
green on
The battery unit is fully charged.
FJBU status
indicator
1
orange
flashing
A battery unit failure has been detected.
Possible causes:
–
–
Capacity failure
Overheating
orange on
A general battery failure has occurred.
TX1330 M3
Operating Manual
75
Starting up and operation
6.3
Switching the server on and off
V
CAUTION!
●
If nothing appears on the screen but flickering stripes after switching
on the server, switch the server off immediately (see chapter
●
The On/Off button does not disconnect the server from the mains
voltage. To completely disconnect it from the mains voltage, remove
the power plug(s) from all PSU inlet connectors.
●
●
Do not move, strike, or shake the server when it is turned on. This can
damage the hard disk in the server and cause data loss.
Turn the server on when the temperature is within its operating
environment range (10–35°C). For details on the operating
environment, refer to "Safety Precautions". When operating the
device outside of this operating environment, the server may operate
improperly and data loss may occur. Furthermore, Fujitsu cannot be
held responsible for any related damage, malfunction, or loss of data,
etc.
●
●
Be sure to wait for 10 seconds or more after shutdown before turning
the server on again.
After connecting all power cords, wait at least 10 seconds before
pressing the On/Off button.
Switching the server on
(standby mode) when the server is connected to the mains.
I
It takes about 60 seconds until power-on becomes possible.
–
Starting up for the first time:
For the Japanese market, please refer to " はじめにお読み く だ さい ".
Ê
Ê
Insert ServerView Suite DVD in the DVD drive.
76
OperatingManual
TX1330 M3
Starting up and operation
Ê
Follow the on-screen instructions (see also section "Configuring the
–
System already installed:
Ê
The server is switched on, performs a system test and boots the
operating system.
Switching the server off
Ê
Shut down the operating system properly.
The server is switched off automatically and enters standby mode. The
power-on indicator lights up orange.
I
If the operating system does not switch off the server automatically, press
the On/Off button for at least four seconds and/or send a corresponding
control signal.
Other On/Off options
Besides the On/Off button, the server can be switched ON and OFF in the
following ways:
–
Timer-controlled switch-on/off
Using the ServerView Operations Manager or iRMC, you can configure that
the server is switched on/off controlled by timer.
–
–
–
Ring indicator
The server is switched on by an internal or external modem.
Wake up On LAN (WOL)
The server is switched on by a command via the LAN (Magic PacketTM).
After power failure
The server automatically reboots following a power failure (depending on the
settings in the BIOS or in iRMC).
TX1330 M3
Operating Manual
77
Starting up and operation
–
Power button override
The system can be switched off by pressing and holding down the On/Off
button (for approximately 4 - 5 seconds).
V
CAUTION!
There is a risk that data may be lost.
–
iRMC S4
iRMC S4 offers various options for switching the server on and off, e.g. via
the Power On Off page of the iRMC S4 Web interface.
78
OperatingManual
TX1330 M3
Starting up and operation
6.4
Configuring the server
This section contains information about configuring the server and installing the
operating system.
I
Make sure that the power saving functions are disabled in the Power
menu of the BIOS Setup during operation.
6.4.1 Configuring the onboard SATA controller
A SATA controller is integrated on the system board. You can configure the
onboard controller either before or during installation with the ServerView
Installation Manager. Using the ServerView Installation Manager is
recommended.
I
The controller has its own configuration utility. For further information,
refer to the “Embedded MegaRAID Software User’s Guide” (on the
Fujitsu manuals server under x86 Servers - Expansion Cards - Storage
I Adapters - LSI Configuration Software - Embedded MegaRAID Software).
Descriptions of operating systems not covered in the controller manual
are provided in the corresponding readme under:
For Japan:
TX1330 M3
Operating Manual
79
Starting up and operation
6.4.2 Configuring the SAS/SATA RAID controller
(PCIe expansion card)
The server has a SAS/SATA RAID controller with "MegaRAID functionality". You
can configure the SAS/SATA RAID controller either before or during installation
with the ServerView Installation Manager. Using the ServerView Installation
Manager is recommended.
I
A separate utility is available to the controller for MegaRAID
configuration. For further information, refer to the "LSI MegaRAID SAS
Software User Guide" (on the Fujitsu manuals server under x86 Servers -
Expansion Cards - Storage Adapters - LSI Configuration Software).
Further information on modular RAID controllers is provided in the
"Modular RAID Controller Installation Guide" (on the Fujitsu manuals
server under x86 Servers - Expansion Cards - Storage Adapters - LSI SAS /
I SCSI RAID Controllers).
Descriptions of operating systems not covered in the controller manual
are provided in the corresponding readme under:
For Japan:
80
OperatingManual
TX1330 M3
Starting up and operation
6.4.3 Configuring the server and installing the operating
system with the ServerView Installation Manager
Using the ServerView Installation Manager on the ServerView Suite DVD
provided, you can conveniently configure the server and install the operating
system. This includes configuring the server-specific settings using the
ServerView Configuration Manager and configuring the RAID controller using
the ServerView RAID Manager.
Advantages of the ServerView Installation Manager
–
–
–
Wizard assisted configuration of your server hardware and disk arrays
Wizard assisted installation of all leading server operating systems
Wizard-assisted creation of configuration files for unattended installation of
several PRIMERGY servers with identical hardware configurations.
–
Installation of drivers and additional software.
I
The software that can be installed depends on your server’s hardware
I configuration. This configuration is detected automatically.
Descriptions of operating systems not covered in the RAID controller
manual are provided in the corresponding readme files under:
For Japan:
To find out how to operate the ServerView Installation Manager and for further
information, refer to the associated manual.
If you are using the ServerView Installation Manager, you can skip the following
section on how to configure the server and install the operating system.
TX1330 M3
Operating Manual
81
Starting up and operation
6.4.4 Configuring the server and installing the operating
system without the ServerView Installation
Manager
Configure onboard SATA controller
Configure the controller as described in section "Configuring the onboard SATA
Configure SAS/SATA RAID controller with "MegaRAID functionality"
Configure the controller as described in section "Configuring the SAS/SATA
Installing the operating system
Ê
Ê
Ê
Insert the CD/DVD for the operating system you want to install.
Reboot the server.
Follow the instructions on screen and in the manual for the operating
system.
82
OperatingManual
TX1330 M3
Starting up and operation
6.5
Cleaning the server
V
CAUTION!
Switch off the server and disconnect the power plugs from the properly
grounded power outlets.
Do not clean any interior parts yourself; leave this job to a service
technician.
Do not use any cleaning agents that contain abrasives or may corrode
plastic.
Ensure that no liquid enters the system. Ensure that the ventilation areas
of the server and the monitor are clear.
Do not use any cleaning sprays (including flammable types). It may
cause a device failure or a fire.
Clean the keyboard and the mouse with a disinfecting cloth.
Wipe the server and monitor casing with a dry cloth. If particularly dirty, use a
cloth that has been moistened in a mild domestic detergent and then carefully
wrung out.
TX1330 M3
Operating Manual
83
Starting up and operation
84
OperatingManual
TX1330 M3
7
Property and data protection
The floorstand model is protected against unauthorized opening by a lock. Apart
from the lock, the server is also fitted with an intrusion detection switch which
enables the ServerView Operations Manager program to detect and log any
removal of the left cover or housing cover and the cover for the HDD modules.
To prevent it being removed from its location, the floorstand model can be
secured to a fixed object with a steel cable running through a clip on the back.
The rack model is protected against unauthorized access by a lockable rack
door.
To protect the system and data internally against unauthorized access, you can
activate the security functions of the BIOSSetup.
7.1
BIOS Setup security functions
The Security menu in BIOS Setup offers various options for protecting your data
from unauthorized access. By combining these options, you can achieve
optimum protection for your system.
I
A detailed description of the Security menu and how to assign passwords
can be found in the BIOS Setup documentation on the Fujitsu manuals
server.
TX1330 M3
Operating Manual
85
Property and data protection
86
OperatingManual
TX1330 M3
8
Troubleshooting and tips
V
CAUTION!
Follow the safety instructions in the "Safety notes and regulations"
If a fault occurs, attempt to resolve it using the measures described:
–
–
–
in this chapter,
in the documentation for the connected devices,
in the help systems of the software used.
If you fail to correct the problem, proceed as follows:
Ê
Make a list of the steps performed and the circumstances that led to the fault.
Also make a list of any error messages that were displayed.
Ê
Ê
Switch off the server.
Contact our customer service team.
8.1
Power-on indicator remains unlit
The power-on indicator remains dark after you switch on your device.
Power cable incorrectly connected
Ê
Make sure that the power cable(s) is/are correctly connected to the server
and the grounded power outlet(s).
Power supply overloaded
Ê
Ê
Disconnect the server power plug(s) from the grounded power outlet(s).
Wait a few minutes before you plug it/them into the grounded power outlet(s)
again.
Ê
Switch on your server.
TX1330 M3
Operating Manual
87
Troubleshooting and tips
8.2
Server switches itself off
Server Management has detected an error
Ê
Check the error list of System Event Log in ServerView Operations Manager
or in the iRMC web interface, and attempt to eliminate the error.
8.3
Screen remains blank
Monitor is switched off
Switch on your monitor.
Ê
Screen has gone blank
Ê
Press any key on the keyboard.
or
Ê
Deactivate screen saver. Enter the appropriate password.
Brightness control is set to dark
Ê
Set the brightness control on the monitor to light. For detailed information,
refer to the operating manual supplied with your monitor.
Power cable or monitor cable not connected
Ê
Ê
Switch off the monitor and the server.
Check whether the power cable is properly connected to the monitor and to
the grounded power outlet.
Ê
Check whether the monitor cable is properly connected to the server and
monitor (if it is plugged in with a connector). If a separate graphics card is
installed in the server, then the monitor cable must be connected to the
graphics card.
Ê
Switch on the monitor and the server.
88
OperatingManual
TX1330 M3
Troubleshooting and tips
8.4
Flickering stripes on monitor screen
V
CAUTION!
Switch off the server immediately. Risk of damaging the server.
Monitor does not support the set horizontal frequency
Ê
Find out which horizontal frequency your monitor screen supports. You will
find the horizontal frequency (also known as line frequency or horizontal
deflection frequency) in the documentation for your monitor.
Ê
Refer to the documentation for your operating system or the software for the
screen controller for details of how to set the correct horizontal frequency for
your monitor, and follow the procedure accordingly.
8.5
No screen display or display drifts
The wrong horizontal frequency or resolution has been selected for the
monitor or for the application program.
Ê
Find out which horizontal frequency your monitor screen supports. You will
find the horizontal frequency (also known as line frequency or horizontal
deflection frequency) in the documentation for your monitor.
Ê
Refer to the documentation for your operating system or the software for the
screen controller for details of how to set the correct horizontal frequency for
your monitor, and follow the procedure accordingly.
8.6
No mouse pointer displayed on screen
Mouse driver not loaded
Ê
Check whether the mouse driver is properly installed and is activated when
the application program is started. Detailed information can be found in the
user manuals for the mouse, the operating system and the application
program.
TX1330 M3
Operating Manual
89
Troubleshooting and tips
8.7
Incorrect date and time
Ê
Set the date and time in the operating system or in the BIOS Setup under
the Main menu, using System Date and System Time respectively.
I
Note that the operating system may affect the system time. For example,
the operating system time may deviate from the system time under
Linux, and would overwrite the system time in the default setting on
shutdown.
If the date and time are still wrong after the server has been switched off and
back on again, replace the lithium battery (for a description refer to the
"FUJITSU Server PRIMERGY TX1330 M3 Upgrade and Maintenance Manual")
or contact our customer service team.
8.8
Drives reported as “dead” when starting
system
This error message can occur when the onboard SATA controller has RAID
functionality or the server is equipped with a PCI RAID controller.
RAID controller configuration incorrect
Ê
Check and correct the settings for the drives using the RAID controller utility.
Further information is provided in the manual for the RAID controller.
8.9
Added drive reported as defective
RAID controller is not configured for this drive
The drive was probably installed when the system was switched off.
Ê
Reconfigure the RAID controller for the drive using the corresponding utility.
Information is provided in the documentation for the RAID controller.
or
Ê
Remove and reinstall the drive while the system is switched ON.
If the drive continues to be shown as defective, then replace it.
90
OperatingManual
TX1330 M3
Troubleshooting and tips
8.10 Error message on screen
The meaning of the error message is explained in the documentation for the
relevant components and programs on the Fujitsu manuals server.
8.11 Expansion cards or onboard devices not
recognized
When an expansion card is added, other expansion cards or onboard devices
might not be recognized.
Ê
Reinstall the drivers for the expansion cards or onboard devices that are not
recognized.
8.12 Temperature warning
A temperature warning is output to the hardware event log and OS event log, or
ServerView issues a notification of a temperature warning such as by a popup
message
The above log is output or the above notification is issued by ServerView when
the ambient temperature is within 30 to 35°C, which is near the upper limit of the
temperature boundaries (10 to 35°C). This is to notify the administrator before
the ambient temperature actually exceeds the range of the temperature
boundaries.
Ê
Although continued use within the temperature boundaries poses no
problems within itself, reconsider the surrounding environment conditions if
this log is output or if ServerView issues this notification.
8.13 No effect of keyboard or mouse
Typing the keyboard does not display any characters, or the mouse cursor does
not move.
Ê
Check to see whether the keyboard and mouse are connected properly. If
they are not connected or you replaced them yourself, then connect the
cables to the server.
TX1330 M3
Operating Manual
91
Troubleshooting and tips
8.14 Optical drive cannot read data
Ê
Ê
Ê
Check to see whether the CD/DVD/BD is inserted properly. If it is not
inserted, correctly insert the disk so that the label is facing up.
Check to see whether the CD/DVD/BD is not dirty. If it is dirty, wipe it with a
soft, dry cloth.
Check to see whether the CD/DVD/BD is not scratched or bent. If scratched
or damaged, replace the CD/DVD/BD.
92
OperatingManual
TX1330 M3
|
Schumacher Models Sc 600a User Manual
Samsung Us07s8gb User Manual
Panasonic Uf 7100 User Manual
Omega Ftb 1000 User Manual
LG LDE3019ST User Manual
HP ELITEBOOK 8440P User Manual
CRAFTSMAN 247.889720 User Manual
CRAFTSMAN 247.370160 User Manual
BLACK DECKER TRO2000R User Manual
BLACK DECKER PD400LG User Manual