OWNER’S MANUAL
AIR CONDITIONER
(SPLIT TYPE)
For general public use
ENGLISH
EN
Indoor Unit
Outdoor Unit
RAS-10PKVP-E
RAS-13PKVP-E
RAS-16PKVP-E
RAS-18PKVP-E
RAS-07PKVP-ND
RAS-10PKVP-ND
RAS-13PKVP-ND
RAS-16PKVP-ND
RAS-18PKVP-ND
RAS-07PAVP-E
RAS-10PAVP-E
RAS-13PAVP-E
RAS-16PAVP-E
RAS-18PAVP-E
RAS-07PAVP-ND
RAS-10PAVP-ND
RAS-13PAVP-ND
RAS-16PAVP-ND
RAS-18PAVP-ND
ACCESSORIES
Remote controller
Remote controller holder
Batteries (two)
PRECAUTION FOR SAFETY
Store this owner’s manual in a location where it can be easily accessed when needed.
Be sure to read this owner’s manual carefully before operating.
The supplied CD-ROM contains the owner’s manual translated into many languages.
It is recommended that maintenance be performed by a specialist when the unit has been operated for a long time.
Be sure to follow the precautions provided here to avoid safety risks.
The symbols and their meanings are shown below.
It indicates that incorrect use of this unit can result in a high possibility of severe injury(*1)
DANGER
or death.
It indicates that incorrect use of this unit may cause severe injury or death.
WARNING
CAUTION
It indicates that incorrect use of this unit may cause personal injury(*2), or property
damage(*3).
*1: A severe injury refers to blindness, injury, burns (hot or cold), electrical shock, bone fracture, or poisoning that leaves aftereffects
and requires hospitalization or extended out-patient treatment.
*2: Personal injury means a slight accident, burn, or electrical shock which does not require admission or repeated hospital treatment.
*3: Property damage means greater damage which affects assets or resources.
Never do.
Beware of rotating parts
Risk of finger injury
Electrical hazard. Contact with water will cause electric
shock. Do NOT touch with wet hands. Always unplug
when not in use.
Always follow the instructions
Do not get the product wet
DANGER
Do not install, repair, open or remove the cover. It may expose you to dangerous voltages. Ask the dealership or the
specialist to do this.
Turning off the power supply will not prevent potential electric shock.
WARNING
The appliance shall be installed in accordance with national wiring regulation.
Means for disconnection from the supply having a contact separation of at least 3 mm in all poles must be incorporated in
the fixed wiring.
Installation must be requested from the supplying retail dealership or professional installation vendors. Installation requires
special knowledge and skill. If customers install on their own, it can be a cause of fire, electric shock, injury or water
leakage.
Do not disassemble, modify or relocate the unit by yourself. It may become the cause of fire, electric shock, or water
leakage. For repair or relocation, please request service from the supplying retail dealership or a dealership.
When relocating or repairing the unit, please contact the supplying retail dealership. When there is a kink in the wiring, it
may be the cause of electric shock or fire.
1
EN
Do not select a location for installation where flammable gas may leak. If there is any gas leakage or accumulation around
the unit, it can be a cause of fire.
Do not select a location for installation where there may be excessive water or humidity, such as a bathroom. Deterioration
of insulation may be a cause of electric shock or fire.
Earth work should be requested from the supplying retail dealership or professional vendors. Insufficient grounding work
may be the cause of electric shock. Do not connect the earth wire to a gas pipe, water pipe, lightning conductor, or
telephone earth wire.
You must use an independent power outlet for the power supply. If a power outlet other than the independent outlet is used,
it may cause a fire.
Check that the circuit breaker is installed correctly. If the circuit breaker is not properly installed, it may cause an electric
shock. To check the installation method, please contact the supplying retail dealership or the professional vendor who
installed the unit.
During an error (such as a burning odor, not cooling, or not warming), stop operating the unit and turn off the circuit breaker.
Continuous operation may be a cause of fire, or electric shock. Please request repair or service from the supplying retail
dealership.
Do not turn ON/OFF the circuit breaker or operate buttons with a wet hand. It may be a cause of electric shock.
Do not insert any material (metal, paper, or water, etc) into the air outlet or air intake opening. Fan may be rotating at high
speed inside or there are high voltage sections, which may cause an injury or electric shock.
When the air-conditioning unit does not cool or warm, there may be a leakage of refrigerant. Please consult the supplying
retail dealership. The refrigerant used in the air-conditioning unit is safe. It will not leak under normal operating conditions
but if it leaks into the room and contacts a heat source such as a heater, or stove, it may cause a harmful reaction.
When water or other foreign substances enter the internal parts, stop operating the unit immediately and turn off the circuit
breaker. Operating the unit continuously may cause fire or electric shock. Please contact the supplying retail dealership for
repair.
Do not clean the inside of the air-conditioning unit yourself. Please request internal cleaning of the air-conditioning unit from
the supplying retail dealership. Incorrect cleaning may cause breakage of resin parts or insulation defects of electrical parts,
causing water leakage, electric shock or fire.
Do not damage or modify the power cable. Do not connect the cable midway, or use a multiple outlet extension cord that is
shared by other devices. Failure to do so may cause fire.
Do not place heavy objects on the power cable, expose it to heat, or pull it. To do so may cause electrical shock or fire.
Do not expose your body directly to cool air for a long time.
Do not insert your finger or any article into the air inlet/outlet.
CAUTION
Ensure that drained water is discharged. When the discharging water process is not sufficient, water may leak, causing
water damage to furniture. To check that the installation method used is correct, please contact the supplying retail
dealership or the professional vendor who installed the unit.
If the indoor unit piping outlet is exposed due to relocation, close the opening, Touching internal electrical parts may cause
injury or electric shock.
Do not wash the main air-conditioning unit with water. It may cause an electric shock.
Do not place any containers such as a vase containing fluid on the unit. It might cause water to enter the unit and deteriorate
the electrical insulation, causing an electric shock.
When using the unit in a closed room, or operating with other combustion appliances, make sure to open a window
occasionally for ventilation. Insufficient ventilation may cause suffocation due to a lack of oxygen.
Do not use combustion appliances in the direct flow of the air from the air-conditioning unit. Poor combustion of a
combustion appliance may cause suffocation.
Avoid operating for long periods in a high humidity environment (over 80%) such as with the windows or doors open. There
may be condensation on the indoor unit and droplets may fall onto the furniture.
When the unit won’t be used for a long time, turn off the main switch or the circuit breaker.
At least once a year check if the mounting table of the outdoor unit is damaged or not. If a damaged state is ignored, the unit
may fall or over-turn, causing an injury.
EN
2
Stand on a sturdy ladder when attaching/detaching the front panel/air filter/air cleaning filter. Failure to do so may cause a
fall or injury.
Do not stand on the outdoor unit or place anything on the unit. It may be the cause of injury due to falling or over-turning.
Any damage to the unit may cause an electric shock or fire.
Do not place anything around the outdoor unit or allow fallen leaves to accumulate around it. If there are fallen leaves, small
animals could enter and contact internal electrical parts, causing a failure or fire.
Do not place animals and plants in places where wind from the air-conditioning unit flows directly. It may have a negative
influence on the animal or plant.
Do not use for special applications such as storage of food or animals, or to display plants, precision devices, or art objects.
Do not use on ships or in other vehicles. It may cause a failure in the air-conditioning unit. In addition, it may damage these
items.
Do not place other electrical appliances or furniture under the unit. Water droplets might fall, causing damage or failure.
When performing maintenance, you must stop operating the unit and turn off the circuit breaker. Since the fan inside may be
rotating at high speed, it may cause an injury.
After the front panel/air filter is cleaned, wipe away any water and allow to dry. If water remains, it may cause an electric
shock.
Once the front panel is removed, do not touch the metal parts (aluminum fins, etc.) of the unit. It may cause an injury.
When you hear thunder and there might be a lightning strike, stop operating the unit and disconnect the circuit breaker. If
lightning strikes, it may cause a failure.
Do not hang laundry or other objects from the moving panel. The moving panel could fall and cause an injury.
3
EN
NAMES OF PARTS
Outdoor unit
b
a
Refrigerant connecting pipe, electric wires and drain
a
hose
b
c
Air inlet
Air outlet
c
Indoor unit
d
e
f
g
h
i
j
k
l
m
n
o
Humidity sensor/temperature sensor
Front panel
Moving panel
Air filter
e
f
g
d o
Air outlet
Horizontal air flow louver
Vertical air flow louver
Plasma ion charger
Display panel
Infrared signal receiver
Remote controller
Panel support
n
k
j
i
h
l
m
(RAS-***-ND model only)
CAUTION
Use care to avoid burns. A heater is installed on the base plate of the outdoor unit. When the outside air temperature is low, the
heater runs to warm the base plate even if the unit is not operating so that snow does not accumulate inside the outdoor unit.
NAMES AND FUNCTIONS OF INDICATORS AND CONTROLS
ON INDOOR UNIT
Display panel
The operating states are shown below.
a
a
b
c
d
e
RESET button
OPERATION indicator (Green)
TIMER/S.CLEAN indicator (Orange)
PURE indicator (Blue) *1
Infrared signal reciever
*1: If the orange light of the PURE indicator is turned on, this
indicates a problem in the plasma ion charger. Please
b
c
d
e
RESET button
The RESET button has the following function.
• Temporary operation function
Use when you misplace or lose the remote controller, or when its
batteries are used up. () see page 20.)
EN
4
REMOTE CONTROLLER AND ITS FUNCTIONS
a
Infrared signal transmitter
Transmits signals to the indoor unit.
n
Automatic operation button (AUTO)
Press this button to operate the air conditioner
automatically.
(A receiving beep is heard.) () see page 10.)
SLEEP MODE button
Press this button to start sleep mode. () see page 19.)
MY COMFORT button
Press this button to operate the air conditioner according to
the settings stored using the MEMO button. () see
page 16.)
PURE button (PURE)
Press this button to start the electrical air purifying
operation.
Press the button again to stop operation. () see page 13.)
Fan speed button (FAN)
Press this button to select the fan speed. When you select
AUTO, the fan speed is automatically adjusted according to
the room temperature. You can also manually select the
b
button
Press the button to start operation. (A receiving beep is
heard.) Press the button again to stop operation. (A
receiving beep is heard.)
If no receiving sound is heard from the indoor unit, press
the button again.
Mode select button (MODE)
Press this button to select a mode. Each time you press
the button, the modes cycle in order from A: Auto
o
p
c
d
q
r
changeover control,
back to A.
: COOL,
: DRY,
: HEAT and
(A receiving beep is heard.)
TEMP
Temperature button (
)
.. The temperature setting is raised to 30°C.
... The temperature setting is lowered to 17°C.
(A receiving beep is heard.)
Set horizontal air flow button (FIX)
Press this button to adjust the horizontal air flow direction.
(A receiving beep is heard.) () see page 17.)
Set vertical air flow button (FIX)
Press this button to adjust the vertical air flow direction. (A
receiving beep is heard.) () see page 17.)
Auto louver button (SWING)
(LOW , LOW+
HIGH
, MED
, MED+
,
e
f
g
) (A receiving beep is heard.)
s
8°C operation button (8°C)
Press this button to start the 8°C set temperature heating
operation. () see page 12.) (RAS-***-ND model only)
a
Each time you press the SWING button, you can change
the swing mode. (A receiving beep is heard.)
(Vertical swing —> Horizontal swing —> Vertical and
Horizontal swing —> Stop swinging)
Press the button again to stop the swinging mode. (A
receiving beep is heard.) () see page 17.)
ON timer button (ON)
h
i
Use this button to change the clock and ON timer times.
ON
To move up the time, press
of the ON
button.
ON
To move down the time, press
of the ON
button.
OFF timer button (OFF)
Use this button to change the OFF timer times.
q
d
c
b
n
p
OFF
To move up the time, press
of the OFF
button.
OFF
To move down the time, press
of the OFF
button.
j
k
l
m
Reserve button (SET)
o
m
Press this button to store the time settings. (A receiving
beep is heard.)
Cancel button (CLR)
Press this button to cancel the ON timer and OFF timer. (A
receiving beep is heard.)
High power button (Hi POWER)
page 19.)
Memory button (MEMO)
Press this button to ready for storing the settings.
Hold down the button for 3 seconds or more to store the
setting indicated on the remote controller and until the
mark is displayed. () see page 16.)
l
f
g
e
r
j
k
s
i
h
5
EN
NAMES AND FUNCTIONS OF INDICATORS ON REMOTE
CONTROLLER
Display
All indicators, except for the clock time indicator, are displayed by pressing the
button.
a
Transmission mark
This transmission mark ( ) indicates when the remote controller transmits signals to the indoor unit.
b
Mode indicator
Indicates the current operation mode.
• Heat pump models
c
ad b hj
(AUTO: Automatic control, A: Auto changeover control,
: HEAT)
: COOL, : DRY,
c
d
e
Temperature indicator
Indicates the temperature setting (17°C to 30°C).
PURE indicator
Shows that the electrical air purifying operation is in progress.
FAN speed indicator
Indicates the selected fan speed. AUTO or one of five fan speed levels (LOW
,
i
g
e
f
LOW+
, MED
, MED+
, HIGH
) can be shown.
: DRY.
Indicates AUTO when the operating mode is either AUTO or
TIMER and clock time indicator
The time setting for timer operation or the clock time is indicated.
The current time is always indicated except during TIMER operation.
Hi POWER indicator
• In the illustration, all indicators are shown
for purposes of explanation. During
operation, only the relevant indicators are
shown on the remote controller.
f
g
Indicates when Hi POWER operation starts.
Press the Hi POWER button to start and press it again to stop operation.
h
(MEMORY) indicator
Flashes for 3 seconds when the MEMO button is pressed during operation.
The
mark is shown when holding down the button for 3 seconds or more while
the mark is flashing.
Press another button to turn off the mark.
i
j
SLEEP MODE indicator
Indicates when the SLEEP MODE is activated.
Press the SLEEP MODE button to start and press it again to stop operation.
A. B change indicator remote controller
• When the remote controller switching function is set, “B” appears in the remote
controller display. (When the remote controller setting is “A”, there is no
indication at this position.)
Remote controller switching function
• If two indoor units are installed in the same room or adjoining rooms, both units may start and stop at the same time when
the remote controller is operated. This can be prevented by setting the switching function so that each indoor unit is
operated only by the corresponding remote controller.
• To use the remote controller switching function, contact the air conditioner dealer or the installation company.
EN
6
PREPARATION AND CHECK BEFORE USE
Loading the remote controller batteries
a
Remove the cover, and insert the batteries.
b
Reattach the cover.
Removing the batteries
a
Remove the cover, and take out the batteries.
b
Reattach the cover.
* Please dispose of the batteries according to the local
regulation.
Batteries
• To replace the batteries, use two new batteries (AAA type).
• The batteries will last about one year under normal usage.
• Replace the batteries if there is no receiving beep from the indoor unit or when the air conditioner cannot be operated using the
remote controller.
• To avoid malfunctions due to battery leakage, remove the batteries when not using the remote controller for over one month.
• Slide off the cover while pressing the sides.
• Battery replacement
Be careful not to reverse the (+) position and the (–) position.
Setting the clock
Before you start operating the air conditioner, set the clock of the remote controller using
the procedures given in this section. The clock panel on the remote controller will
indicate the time regardless of whether the air conditioner is in use or not.
Initial setting
When batteries are inserted in the remote controller, the clock panel displays AM 0:00
and flashes.
ON
OFF
a
ON
button (or OFF
button)
ON
OFF
Press the ON
button (or OFF
button) to set the current time.
Each press of the ON button (or OFF button) changes the time in one minute
increments.
Holding down the ON button (or OFF button) changes the time in ten minute
increments.
b
a
SET
b
SET
button
SET
Press the SET
button.
The current time is displayed and the clock starts.
7
EN
Adjusting the clock
a
CLOCK button
Press the CLOCK button.
The clock time indicator flashes.
ON
OFF
b
ON
button (or OFF
button)
ON
OFF
Press the ON
button (or OFF
button) to set
the current time.
Each press of the ON button (or OFF button)
changes the time in one minute increments.
Holding down the ON button (or OFF button)
changes the time in ten minute increments.
Push CLOCK
SET
c
SET
button
b
a
SET
Press the SET
button.
c
The current time is displayed and the clock starts.
EN
8
USING THE REMOTE CONTROLLER
CAUTION
• The air conditioner will not operate if curtains, doors or other objects block the signals from the remote controller to the indoor
unit.
• Be careful that liquids do not spill onto the remote controller.
• Do not expose the remote controller to direct sunlight or heat.
If the infrared signal receiver on the indoor unit is exposed to direct sunlight, the air conditioner may not function properly.
Use curtains to prevent sunlight from reaching the receiver.
• Signals may not be properly received, if the room using the air conditioner has fluorescent lighting with electronic starters. If
you plan to use fluorescent lamps, consult with your local dealer.
• If other electrical appliances are activated by the remote controller, move these appliances or consult with your local dealer.
Location of the remote controller
• Keep the remote controller where its signals can reach the receiver of the indoor
unit (a distance of up to 7 m is allowed).
• When you select timer operation, the remote controller automatically transmits a
signal to the indoor unit at the specified time.
If you keep the remote controller in a location where proper signal transmission is
blocked, a time lag of up to 15 minutes may occur.
7 m
Remote controller holder
Installing the remote controller holder
• Before you actually install the remote controller holder on a wall or pillar, check
whether the remote controller signals can be received by the indoor unit.
Mounting and removing the remote controller
• To mount the remote controller, hold it parallel to the remote controller holder and
push it in fully. To remove the remote controller, slide the remote controller
upwards and out from the holder.
Types of signal receiving tones
When the receiver of the indoor unit receives a signal, a signal receiving tone is made from the indoor unit.
Beep ....................... Start/Change
Prolonged beep ...... Stop
Beep-beep .............. Notify
When the notification sound beep-beep is made
• This indicates that the temperature, fan speed, or air flow direction settings were returned to the basic settings.
Item
Basic setting
Temperature
Fan speed
22°C (8°C···8°C OPERATION (RAS-***-ND model only))
AUTO
Horizontal air flow
Vertical air flow
When the horizontal air flow louver faces the front.
When the vertical air flow louver stops at the louver limit
position.
9
EN
AUTOMATIC OPERATION
When you set the air conditioner to AUTO mode, it automatically selects cooling, heating, or fan only operation depending on the room
temperature. () see page 19.)
The fan speed and louver are also automatically controlled.
Start
a
button
Press this button to start the air conditioner.
AUTO button (AUTO)
Press AUTO button.
b
TEMP
c
Temperature button (
)
Set the desired temperature.
b
c
• The OPERATION indicator (green) on the display panel of the indoor unit lights. The
operating mode is selected according to the room temperature and operation starts
after approximately 3 minutes.
• If the AUTO mode is uncomfortable, you can select the desired conditions manually.
The fan speed and louver position can be changed, and MODE is also changed from
AUTO to A when the fan speed or louver position is changed.
The fan speed indicator is also shown.
a
Stop
button
Press this button again to stop the air conditioner.
AUTOMATIC OPERATION (AUTO CHANGEOVER)
When you set the air conditioner to A mode or switch over from AUTO operation because of a change in settings, the air conditioner
automatically selects cooling or heating operation depending on the room temperature. () see page 19.)
Start
a
button
Press this button to start the air conditioner.
Mode select button (MODE)
Select A.
b
TEMP
c
d
Temperature button (
)
Set the desired temperature.
Fan speed button (FAN)
Select one of “AUTO” LOW , LOW+
, MED
, MED+
,
HIGH
.
c
b
a
• The OPERATION indicator (green) on the display panel of the indoor unit lights. The
operating mode is selected according to the room temperature and operation starts
after approximately 3 minutes.
• The temperature, fan speed and louver position can be changed. You can select the
desired conditions manually.
d
Stop
button
Press this button again to stop the air conditioner.
EN
10
COOLING/HEATING OPERATION
Start
a
button
Press this button to start the air conditioner.
Mode select button (MODE)
b
Select COOL
or HEAT
.
TEMP
c
d
Temperature button (
)
Set the desired temperature.
Fan speed button (FAN)
c
b
a
Select one of “AUTO” LOW , LOW+
HIGH
, MED
, MED+
,
.
d
• The OPERATION indicator (green) on the display panel of the indoor unit turns on.
Operation starts after approximately 3 minutes.
Stop
button
Press this button again to stop the air conditioner.
DRY OPERATION
Start
a
button
Press this button to start the air conditioner.
Mode select button (MODE)
b
Select DRY
.
TEMP
c
Temperature button (
)
Set the desired temperature.
c
b
a
• The fan speed setting is fixed to AUTO and the AUTO is displayed.
• The OPERATION indicator (green) on the display panel of the indoor unit turns on, and
operation starts after approximately 3 minutes.
Stop
button
Press this button again to stop the air conditioner.
11
EN
8°C OPERATION (RAS-***-ND model only)
This function is usable for prevention of freeze of an uninhabited room.
Press this button to start the 8°C set temperature heating operation.
The air conditioner controls the room temperature to about 8°C.
The room temperature may deviate slightly from 8°C depending on the size of the room
and the installation condition of the unit.
Starting the 8°C heating operation while the air conditioner is stopped
Start
a
8°C button
Press this button to start the 8°C set temperature heating operation.
• The OPERATION indicator (green) on the display panel of the indoor unit turns on.
Operation starts after approximately 3 minutes.
Stop
a
button
Press this button to stop the air conditioner.
If the 8°C heating operation starts while the air conditioner is stopped, press the 8°C button again to stop the operation.
Starting the 8°C heating operation while the air conditioner is operating
Start
a
8°C button
Press this button to change to the 8°C set temperature heating operation.
• If the air conditioner performs a cooling (including automatic cooling) or dry operation, it stops and the 8°C set temperature heating
operation starts after approximately 3 minutes. If the air conditioner performs a heating operation, it changes immediately to the 8°C
heating operation.
• If the air conditioner performs a PURE operation, it performs both the pure operation and 8°C heating.
Stop
button
Press this button to stop the air conditioner.
If the 8°C heating operation starts while the air conditioner is operating, press the 8°C button again to return to the previous operating
condition.
Check the operating condition on the screen of the remote control.
When a heating operation starts from 8°C heating, it can take approximately 5 minutes for the warm air to start blowing.
CAUTION
The heating performance could worsen if the louver direction is too high during 8°C heating operation.
NOTE
• The fan speed at the start of 8°C heating is operated with AUTO.
• If a timer operation is set to before the 8°C heating operation, the timer operation setting is cancelled. Timer operation
settings cannot be made during 8°C heating operation.
• Settings for SWING (louver swing), FIX (louver position), FAN (fan speed) and PURE (pure operation) can be changed
during 8°C heating operation. Setting changes cannot be made with other buttons.
• Temperature can be changed from 5°C to 13°C during 8°C heating operation.
• The temperature of the blown air is lower than during normal heating operation.
EN
12
PURE OPERATION
Press this button to start the electrical air purifying operation.
During air conditioner operation
a
PURE button
PURE operation starts by pressing this button.
• The PURE indicator (blue) on the display panel of the indoor unit turns on.
• Plasma ion charger is activated.
To stop only PURE operation
PURE button
PURE operation stops by pressing this button.
• The PURE indicator (blue) on the display panel of the indoor unit turns off, while air
conditioner is operating.
a
• Plasma ion charger is deactivated.
To stop air conditioner operation at the same time
button
Air conditioner operation and PURE operation stop by pressing this button.
• The OPERATION indicator (green) and PURE indicator (blue) on the display panel of
the indoor unit turn off.
CAUTION
• When the
button is pressed the next time, operation starts with the combined
air conditioner and PURE operation.
• During the combined air conditioner and PURE operation, air conditioner operation
only cannot be stopped.
When the air conditioner is stopped
a
PURE button
PURE operation starts by pressing this button.
• The PURE indicator (blue) on the display panel of the indoor unit turns on.
INFORMATION
• During PURE operation, a small amount of ozone is produced, and you might notice the smell.
• When the fan speed is automatic, it changes up to MED+
.
• During Hi POWER operation, the position of the vertical air flow louver changes to the high power position.
Hi POWER OPERATION
High power (Hi POWER)
• The Hi POWER (high power operation) mode automatically controls room temperature,
air flow and the operation mode so that the room is quickly cooled in summer and
warmed in winter. () see page 19.)
Setting Hi POWER mode
a
Hi POWER button
Press the Hi POWER button. The Hi POWER mark on the remote controller is
shown.
Canceling Hi POWER mode
a
Hi POWER button
Press the Hi POWER button once again.
The Hi POWER mark on the remote controller turns off.
CAUTION
a
The Hi POWER mode cannot be activated during DRY operation.
13
EN
TIMER OPERATION
ON timer and OFF timer
Setting the ON Timer
ON
a
ON
button
ON
Press the ON
button. Set the timer to the desired time.
Each time the ON button is pressed, the time changes in ten minute increments.
Holding down the ON button changes the time in one hour increments.
SET
b
c
SET
button
SET
Press the SET
The timer time is displayed, and the timer starts.
button to set the timer.
CLR
CLR
button
CLR
Press the CLR
button to cancel the timer setting.
Setting OFF Timer
b
c
a
OFF
a
OFF
button
OFF
Press the OFF
button.
Set the timer to the desired time.
Each time the OFF button is pressed, the time changes in ten minute increments.
Holding down the OFF button changes the time in one hour increments.
SET
b
SET
button
SET
Press the SET
button to set the timer.
The timer time is displayed, and the timer starts.
CLR
c
CLR
button
CLR
Press the CLR
button to cancel the timer setting.
.
CAUTION
• When you select timer operation, the remote controller automatically transmits the timer signal to the indoor unit at the
specified time. Therefore, keep the remote controller in a location where it can transmit the signal to the indoor unit
properly.
SET
• If you do not press the SET
Once you select timer operation mode, the settings are saved in the remote controller.
Thereafter, the air conditioner will start operating under the same conditions as you adjusted by the
controller.
OFF
ON
or
button on the remote
You cannot set the timer when the clock display is flashing.
Follow the instructions in the section “Setting the clock” on page 7 to set the clock, and then set the timer.
EN
14
Combined timer (Setting the ON and OFF timers simultaneously)
OFF timer —> ON timer
(Operation —> Stop —> Operation)
This feature is useful when you want to stop the air conditioner after you go to sleep, and start it again in the morning when you wake
up or you return home.
Example:
To stop the air conditioner and start it again next morning
Setting combined TIMER
Operation
Operation again
OFF
(1) Press the OFF
button to set the OFF timer.
button to set the ON timer.
Stop
ON
(2) Press the ON
(3) Press the SET
SET
button.
ON timer —> OFF timer
(Stop —> Operation —> Stop)
You can use this setting to start the air conditioner when you wake up and stop it when you leave the house.
Example:
To start the air conditioner the next morning and stop it
Setting combined TIMER
Operation
ON
(1) Press the ON
button to set the ON timer.
button to set the OFF timer.
Stop
Stop
OFF
(2) Press the OFF
(3) Press the SET
SET
button.
• The ON or OFF timer function that is closer to the current time is
activated first.
• If the same time is set for both ON and OFF timers, no timer
operation is performed. Also, the air conditioner may stop
operating.
CAUTION
Approximately 3 seconds later, the remote controller will
transmit the signal to the indoor unit and a receiving beep
will sound from the indoor unit after you press the
SET
SET
button.
Daily combined timer (setting the ON and OFF timers simultaneously and activating every day)
This feature is useful when you want to use the combined timers at the same time every day.
Setting combined TIMER
ON
(1) Press the ON
button to set the ON timer.
button to set the OFF timer.
OFF
(2) Press the OFF
(3) Press the SET
SET
button.
(4) After step (3), an arrow mark ( or ) flashes for about 3 seconds. Press the
SET
SET
button during this flashing.
• Both arrows (
,
) are shown while the daily timer is activated.
Cancelling timer operation
CLR
Press the CLR
button.
Clock display
During TIMER operation (ON-OFF, OFF-ON, OFF timer), the clock time indicator is not
shown so the setting time can be displayed. To view the current time, press the SET
button briefly and the current time will be displayed for about 3 seconds.
15
EN
MEMORY/MY COMFORT OPERATION
Use the MEMO button to store a frequently used operation setting for convenience.
Start the air conditioner in the operation mode that you want the remote controller to
store.
Press the button as shown below while the air conditioner is operating.
a
MEMO button
Press this button briefly to ready for storing the setting.
All the icons currently shown flash, except for the clock time indicator and mode
indicator.
b
MEMO button
Hold down the MEMO button for 3 seconds or more while the indicator flashes.
The
mark is shown and the setting is stored.
• If you do not press the MEMO button within 3 seconds or if you press another button,
the MEMORY setting is cancelled.
• Operation modes which can be stored with the MEMO button are MODE, Temperature,
FAN, TIMER and Hi POWER.
a
b
To operate the air conditioner with the setting stored using the MEMO button.
a
MY COMFORT button
Press the MY COMFORT button. The setting stored with the MEMO button will be
shown and the air conditioner operates based on the setting.
(A): When the MY COMFORT button is pressed while operation is stopped
• The OPERATION indicator (green) on the display panel of the indoor unit turns on, and
operation starts after approximately 3 minutes.
(B): When the MY COMFORT button is pressed during operation
• The operation mode changes to the setting stored with the MEMO button.
• Initial setting:
a
MODE
: AUTO
Temperature : 22
EN
16
ADJUSTING AIR FLOW DIRECTION
• Adjust the air flow direction properly. Failure to do so could cause discomfort
and make an uneven room temperature distribution.
• Adjust the vertical air flow using the remote controller.
• Adjust the horizontal air flow using the remote controller.
Adjusting the vertical air flow
The air conditioner automatically adjusts the vertical air flow direction according
to the operating conditions when AUTO or A mode is selected.
Adjusting the horizontal air flow
Preparation:
• While the air conditioner is operating, you can use the remote controller to
change the air flow in the horizontal (left/right) direction.
To set a selected vertical air flow direction
Use this function when the air conditioner is operating.
a
FIX
button
a
b
Hold down or briefly press the FIX button on the remote controller to move
the louver in the desired direction.
To set a selected horizontal air flow direction
Use this function when the air conditioner is operating.
b
FIX
button
Hold down or briefly press the FIX button on the remote controller to move
the louver in the desired direction.
NOTE
• Change the vertical/horizontal air flow louver direction within the range
indicated.
• In subsequent operations, the vertical/horizontal air flow is automatically set
to the direction that you set the louver using the FIX button.
To automatically swing the air flow direction
Perform this function when the air conditioner is operating.
c
SWING button
Each time you press the SWING button, the air conditioner’s operation mode
is changed as follows:
• The vertical air flow louver swings.
c
• The horizontal air flow louver swings.
• The vertical air flow louver and horizontal air flow louver swing at the same
time.
When the vertical air
• The swinging of the vertical air flow louver and horizontal air flow louver is
stopped.
• Press FIX
swinging.
flow louver is opened with the FIX
button, it reverses direction while
opening.
to change the center position of the vertical air flow louver
• Press FIX
swinging.
to change the center position of the horizontal air flow louver
• To stop the function, press the SWING button.
CAUTION
• The FIX and SWING buttons will be disabled when the air conditioner is not
operating (including when ON TIMER is set).
• Do not operate the air conditioner for an extended period of time with the air
flow direction set downward during the cooling or dry operation. Otherwise,
condensation may occur on the surface of the vertical air flow louver and
cause water dripping.
• Do not move the vertical air flow louver and horizontal air flow louver
manually. Always use the FIX button.
If you move the louver manually, it may malfunction during operation.
If the louver malfunctions, stop the air conditioner once, and restart.
• When the air conditioner is started immediately after it was stopped, the
vertical air flow louver might not move for about 10 seconds.
17
EN
AUTO RESTART OPERATION
This air conditioner is equipped with an automatic restarting function which allows the air conditioner to resume without the use of the
remote controller under the operating settings in the event of a power shutdown. Operation resumes without warning 3 minutes after
power is restored.
INFORMATION
The AUTO RESTART OPERATION is not set to work at factory shipment, and so it is necessary to set it to this function if
required.
HOW TO SET AUTO RESTART
To set the auto restart function, proceed as follows:
The power supply to the unit must be on. The function will not be set if the power is off.
To enable the auto restart function, hold down the RESET button for 3 seconds.
The air conditioner receives the setting and beeps 3 times. Now the auto restart
setting is activated. The system can restart automatically.
(1) When the air conditioner is in stand-by (not running).
Hold down the RESET button for 3 seconds or more.
• The air conditioner starts to operate. The green indicator turns on.
• After about 3 seconds, the air conditioner beeps 3 times.
The green indicator flashes for 5 seconds.
RESET
button
• The air conditioner is operating.
If the air conditioner is not required to run at this time, push the RESET button
again or use the remote controller to stop the air conditioner.
(2) When the air conditioner is operating.
Hold down the RESET button for 3 seconds or more.
• The air conditioner stops operating. The green indicator turns off.
• 3 seconds after pushing the button, the air conditioner beeps 3 times.
The green indicator flashes for 5 seconds
• The air conditioner stops.
If you do not need the air conditioner to stop at this time, use the remote controller to restart the air conditioner. During the
subsequent operation, the green indicator is turned on.
• The auto restart operation will not accept a command if timer operation with the remote controller is activated.
• After restarting the air conditioner by the AUTO RESTART OPERATION, the louver swing (AUTO) operation resumes.
HOW TO CANCEL AUTO RESTART
To cancel the auto restart operation, proceed as follows:
Repeat the setting procedure. The air conditioner receives the setting and beeps 3 times.
Now the auto restart setting is cancelled.
The air conditioner needs to be manually restarted with the remote controller after the main supply is turned off.
(1) When the air conditioner is in stand-by (not running).
Hold down the RESET button for 3 seconds or more.
• The air conditioner starts to operate.
The green indicator will turn on.
• After about 3 seconds, the air conditioner beeps 3 times.
• The air conditioner is operating.
If the air conditioner is not required to run at this time, push the RESET button
again or use remote controller to stop the air conditioner.
(2) When the air conditioner is operating.
RESET
button
Hold down the RESET button for 3 seconds or more.
• The air conditioner stops operating.
The green indicator is turned off.
• After about 3 seconds, the air conditioner beeps 3 times.
• The air conditioner stops.
If you do not need the air conditioner to stop at this time, use the remote controller
to restart the air conditioner.
During subsequent operation, the green indicator is turned on.
INFORMATION
Do not hold down the RESET button for more than 10 seconds. Otherwise, the forced cooling operation used during
servicing and re-installation will activate.
To stop the forced cooling operation, press the RESET button again.
EN
18
HOW THE AIR CONDITIONER WORKS
Automatic Operation
As shown in Figure 1, Automatic Operation mode selects the operation based on the room temperature data when operation begins.
Room temperature when operation begins
or when selected again
Room temperature
Cooling operation
Setting temperature+1
Setting temperature
Fan only operation
Heating operation
Setting temperature–1
Figure 1
The operation mode is selected again after the compressor has remained stopped for 15 minutes.
Hi POWER operation
When you press the Hi POWER button during cooling, heating or A operation, the air conditioner starts the following operation.
• Cooling operation
The cooling operation is performed at 1°C lower than the temperature setting.
The fan speed is also set to high*.
* The noise level raises, according to the fan speed.
• Heating operation
The heating operation is performed at 2°C higher than the temperature setting.
The fan speed is automatically switched according to the operating condition.
SLEEP MODE operation
The air conditioner automatically controls the room temperature, air flow and noise level, to prevent overcooling in summer and
maintain a warm and comfortable room in winter.
INFORMATION
• The power and noise level are reduced during sleep mode, so the room may not be cooled sufficiently if the mode is used for
a long period of time.
• The sleep mode cannot be used during dry operation, PURE operation (independent operation).
(PURE operation (independent operation) is when the PURE button is pressed while the air conditioner is stopped to perform
PURE operation by itself. The air conditioner does not operate at this time.)
• If the FAN button is pressed during sleep mode, the sleep mode is canceled.
• Sleep mode is not a timer operation.
Dry operation (
)
The dry mode automatically selects the cooling dry operation based on the difference between the temperature setting and the actual
room temperature.
The fan speed indicator shows AUTO, and low speed is used.
• The display panel indicators will decrease in brightness in sleep mode.
19
EN
HINTS FOR ECONOMICAL OPERATION
Chilly
Maintain room temperature at a comfortable level
Please clean
Control
Clean the air filters
Clogged air filters impair the performance of the air conditioner. Clean
them every two weeks.
Use the timer
effectively
Never open doors and windows more than necessary
To keep cool or warm air in the room, never open doors and windows more
than necessary.
Window curtains
During cooling operation, close the curtains to avoid direct sunlight.
During heating operation, close the curtains to keep the heat in.
Use the timer effectively
Blows upward
Set the timer for the desired operating time.
Allow uniform circulation of room air
Adjust the air flow direction for even circulation of room air.
Air flow
adjustment
Blows downward
TEMPORARY OPERATION
I cannot find
the remote
controller
Temporary operation
This function is used to operate the unit temporarily in case you misplace the remote
controller or the batteries are used up.
• Push the RESET button to start the automatic operation (AUTO).
• While the temporary operation is activated, the remote controller operation is disabled.
A temporary
operation feature is
provided!
INFORMATION
Do not hold down the RESET button for more than 3 seconds. () see page 18.)
CLEANING OPERATION
Cleaning operation
This function is used to dry the inside of the air conditioner to reduce the growth of mold, etc. inside the air conditioner.
• When the unit shuts down after having operated for 10 or more minutes in the cooling or dry mode, the cleaning operation is started
automatically, and the S.CLEAN indicator on the unit’s display panel turns on.
Cleaning operation duration
• The cleaning operation lasts for 4 hours if the unit has been operating in the cooling or dry mode for 10 minutes or more.
About the cleaning operation
• The cleaning operation will not make the room cleaner or remove the mold and dust already inside the air conditioner.
• During operation, a small amount of frost may be visible: this is normal and does not indicate a malfunction.
• The vertical airflow louvers and moving panel open slightly.
• If an ongoing cleaning operation is suspended, the effect of the cleaning will be compromised.
• To forcibly stop the cleaning operation, press the
button twice during the cleaning operation.
EN
20
USUAL MAINTENANCE
WARNING
Before you clean the air conditioner, be sure to turn off the circuit breaker or main power switch.
Wipe with a dry cloth
Cleaning of indoor unit and remote controller
CAUTION
• Use a dry cloth to wipe the indoor unit and remote controller.
• When the air conditioner is extremely dirty, use a cloth dipped in cold water to wipe the indoor
unit.
Thinner
• Never use a damp cloth on the remote controller.
• Do not use a chemical-based duster for wiping or leave such materials on the unit for extended
periods of time. Doing so could damage or cause the surface of the unit to fade.
• Do not use benzine, thinner, polishing powder, or other solvents for cleaning.
These can cause the plastic surface to crack or deform.
Cooling with
high
temperature
setting.
When not using the unit for at least 1 month
(1) Perform fan operation for 3 to 4 hours to dry the inside of the unit.
• If a high temperature setting is used with cooling operation, fan operation is performed.
(2) Stop the air conditioner and turn off the circuit breaker.
(3) Clean the air filters.
(4) Remove the batteries from the remote controller.
Check before operation
CAUTION
Air
filter
• Check that the air filters are installed.
• Check that the air outlet and inlet of the outdoor unit are not blocked.
Cleaning the air filter
Clean the air filters every 2 weeks.
The performance of the air conditioner will degrade if the air filters are covered with dust.
Clean the air filters as often as possible.
21
EN
Preparation:
1
2
3
Open the moving panel.
Pull the handles on the bottom of the right and left sides, and open the moving panel
until it is horizontal.
Be sure to always grasp the handles when opening the moving panel.
(The moving panel cannot be removed.)
Front panel
Handle
Moving panel
Support the moving panel with the panel support.
Grasp the moving panel with your left hand, and use your right hand
to pull up the panel support and fit it into the slot.
Panel support
Slot
4
5
Remove the air filter.
Lift the air filter knob, and pull it out to the front.
Use a vacuum cleaner to remove the dust from the filters or wash them with water.
After washing the air filters, dry them in the shade.
6
7
Insert the top section of the air filter so that its right and left edges fit on the indoor unit.
Close the moving panel.
Grasp the moving panel with your left hand, and use your right hand to lower the panel support downward, and push on the two
locations shown in the figure to close it. If the moving panel is opened, use the remote control to perform the start and stop
operations.
(The moving panel can be damaged if you try to close it with your hand while it is
open.)
PUSH
PUSH
EN
22
AIR CONDITIONER OPERATION AND PERFORMANCE
Three-minute protection feature
A protection feature is provided that prevents the air conditioner from being activated for approximately 3 minutes when it is restarted
immediately after operation or when the power supply switch is set to on. This is used to protect the machine.
Heating characteristics
Preheating operation
The air conditioner does not deliver warm air immediately after it is started.
Warm air flows out after approximately 5 minutes when the indoor heat exchanger has warmed up.
Warm air control
When the room temperature reaches the temperature setting, the fan indoor speed is automatically reduced.
The outdoor unit is stopped at this time.
Defrosting
If frost has formed on the outdoor unit during the heating operation, defrosting is started automatically (for approximately 5 to 10
minutes) to maintain the heating effect.
• The fans in both the indoor and outdoor units stop during the defrost operation.
• During the defrost operation, defrosted water is drained from the bottom plate of the outdoor unit.
Heating capacity
In the heating operation, heat is absorbed from outdoors and released into the room. That is called the heat pump system. When the
outdoor temperature is too low, usage of another heating apparatus in combination with the air conditioner is recommended.
Consideration for accumulated snow
Select the position for the outdoor unit where it will not be subjected to snow drifts, accumulation of leaves or other seasonal debris. It
is important that the air flow of the outdoor unit is not blocked as this will result in reduced heating or cooling performance. During the
heating mode and at sub-zero temperatures, the water drained off the outdoor unit as a result of the automatic defrost may
accumulate and freeze. It is important that adequate drainage or a soak-way be provided.
(RAS-***-ND model only)
CAUTION
A heater is installed on the base plate of the outdoor unit. When the outside air temperature is low, the heater runs to warm the
base plate even if the unit is not operating so that snow does not accumulate inside the outdoor unit. Do not use the supplied
drain nipple for draining water. Drain the water from all the drain holes directly. Provide a space of at least 50 cm under the
outdoor unit so that the draining water does not freeze and block the drain holes.
Power failure
Power failure during operation stops the unit completely.
• The OPERATION indicator (green) on the indoor unit starts flashing when power is restored.
• To restart operation, push the
• Lightning or a car wireless telephone operating nearby may cause the unit to malfunction. Turn the power supply switch off and then
on again. Push the button on the remote controller to restart.
button on the remote controller.
Air conditioner operating conditions
For proper performance, operate the air conditioner under the following temperature conditions.
Cooling operation
Outdoor temperature: –10°C to 46°C
Room temperature: 21°C to 32°C
CAUTION
Room relative humidity — less than 80%. If the air conditioner operates outside this
range, the surface of the air conditioner may attract condensation.
Heating operation
Dry operation
8°C Heating
Outdoor temperature: –15°C to 24°C
Room temperature: Less than 28°C
Outdoor temperature: –10°C to 46°C
Room temperature: 21°C to 32°C
Setting temperature: 5°C to 13°C
If the air conditioner is used in conditions other than above, the safety protection functions may be activated.
23
EN
TROUBLESHOOTING
CAUTION
If any of the following conditions occur, stop the air conditioner immediately, turn off the main power switch and contact the
dealer.
• The indicators flash at short intervals (5 Hz). Reset the circuit breaker 2 to 3 minutes after the power main switch is turned off.
Despite the resetting operation, the indicators still continue turning on and off.
• The main power fuse often blows, or the circuit breaker is often activated.
• Foreign matter or water has fallen inside the air conditioner.
• Any other unusual conditions are observed.
Before asking for servicing or repairs, check the following points.
Inoperative
• The power main switch is turned off.
• The circuit breaker is activated to cut off the power supply.
• The main power fuse has blown.
• The electric current has stopped.
• The batteries in the remote controller used up.
• The ON timer is set.
• As a protective mechanism for the air conditioner, it does not operate for 3 minutes
immediately after restarting operation or turning on the main power.
Poor cooling or heating performance
• The air inlet or outlet of the outdoor unit is blocked.
• Doors or windows are opened.
• The air filter is clogged with dust.
• The louver is not at the correct position.
• The fan speed is set to low.
• The air conditioner is set to the DRY or SLEEP MODE.
• The temperature setting is too high (during cooling operation).
• The temperature setting is too low (during heating operation).
• Is the air conditioner being used outside its operating conditions? () see page 23.)
• The protective device may be activated if there is a change in voltage, the air inlet is
blocked, or other condition causes an excessive load on the machine.
Remove the cause of the problem, and after about 30 seconds, turn on the circuit
breaker again.
EN
24
Before asking for servicing or repairs, check the following points.
Condensation forms on the back of the indoor unit.
• Condensation on the back of the indoor unit is automatically collected and drained out.
Indoor unit or outdoor unit makes a strange noise.
• When the temperature changes sharply, the indoor or outdoor unit may make a strange
noise (such as a tit-tack noise or flowing noise) because of the expansion/contraction of
parts or change in refrigerant flow.
The room air smells.
A bad odor comes from the air conditioner.
• Smells absorbed in the wall, carpet, furniture, clothing, or furs are coming out.
• During PURE operation, a small amount of ozone is produced, and you might notice the
smell.
The OPERATION indicator turns on and off.
• The indicator turns on and off (1 Hz) when power is restored after a power failure or when
the power main switch is set to on.
Frost forms on the outdoor unit during heating operation.
Water is drained from the outdoor unit.
• Frost sometimes forms on the outdoor unit during heating operation. In that case, the unit
automatically performs defrosting (for 2 to 10 minutes) for improving the heating efficiency.
• In the defrosting operation, the airflow from both the indoor and outdoor units stops.
• A hiss sound is heard when the flow of the refrigerant is changed for defrosting.
• The water resulting from automatic defrosting during the heating operation is drained from
the outdoor unit.
The air flow changes even though the FAN button is not set to the AUTO mode.
• When the temperature of the blown air goes down during heating operation, the air
conditioner automatically changes or stops the air flow from the indoor unit so that the
people in the room do not feel chilly.
A white mist of chilled air or water is generated from the outdoor unit.
• Steam is sometimes generated from the indoor unit during cooling operation or the
outdoor unit during defrosting operation.
Automatic operation of vertical air flow louvers
• When the room temperature or outdoor temperature is high during the heating operation,
the vertical air flow louvers close once and then set themselves automatically to the
original position setting again.
25
EN
Before asking for servicing or repairs, check the following points.
The PURE indicator (Orange) turns on.
• The indicator may turn on if the moving panel is not firmly closed.
Sounds made from the indoor unit
• The ion charger unit may make a humming, clicking, or buzzing sound during electrical air purifying or cleaning operation.
• When the power is turned on or the air conditioner is stopped, the vertical air flow louvers may make a rattling sound or
shuttling sound.
• Some parts may expand or shrink due to temperature fluctuations, and this can result in a slapping sound.
• When the refrigerant is flowing, a hissing sound or gurgling sound can result.
• A hissing sound can be made when the air conditioner is switched to defrosting operation during heating operation.
• An operation sound is made when the moving panel is opened and closed.
Sounds made from the outdoor unit
• A rustling sound can be made when the air conditioner is switched to defrosting operation during heating operation.
EN
26
TROUBLESHOOTING (Remote Controller)
Before asking for servicing or repairs, check the following points.
The remote controller does not operate correctly.
Symptoms
Causes
Possible Solution
The operating mode switches.
• Check whether the MODE indicated
on the display is AUTO.
The fan speed and louver direction
cannot be changed in AUTO mode.
When the SWING, FIX or FAN buttons
are pressed in AUTO mode, the mode
changes to A mode.
AUTO
The fan speed cannot be
changed.
• Check whether the MODE indicated
on the display is : DRY.
When dry operation is selected, the air
conditioner automatically selects the
fan speed. The fan speed can be
selected during
HEAT.
COOL and
: DRY
The Display Goes Off
Symptoms
Causes
Description
The indicators on the display
are not shown after a short
time.
• Check whether the timer operation is
over when the OFF TIMER is shown
on the display.
The air conditioner stops since the
setting time has elapsed.
The TIMER display turns off
after a certain period of time.
• Check whether the timer operation
has started when the ON TIMER is
shown on the display.
When the time reaches the time
setting for the ON timer operation, the
air conditioner starts to operate
automatically and the ON timer display
turns off.
: ON
The Signal Receiving Tone Does Not Sound
Symptoms
Causes
Description
No receiving tone is made from
the indoor unit even when the
button is pushed.
• Check whether the infrared signal
transmitter of the remote controller is
properly pointed towards the receiver
Point the infrared signal transmitter of
the remote controller towards the
receiver of the indoor unit, and then
of the indoor unit when the
is pushed.
button
press the
button repeatedly.
27
EN
SPECIFICATIONS
Type
Reverse cycle, Split type
Model
Indoor Unit
Outdoor Unit
Indoor Unit
Outdoor Unit
RAS-07PKVP-E
RAS-07PAVP-E
RAS-10PKVP-E
RAS-10PAVP-E
RAS-07PKVP-ND
RAS-07PAVP-ND
RAS-10PKVP-ND
RAS-10PAVP-ND
Power supply
220–240 V ~50 Hz
220–240 V ~50 Hz
220–230 V ~60 Hz
220–230 V ~60 Hz
Cooling capacity
Heating capacity
Cooling current
Cooling power
Heating current
Heating power
(kW) CAPA.
(kW) CAPA.
2.0
2.5
2.5
3.0
(A)
(W)
(A)
AMP.
0.21–0.19
1.86–1.70
330
0.21–0.19
2.19–2.01
450
WATT.
AMP.
25
0.21–0.19
25
25
0.21–0.19
25
2.35–2.15
415
2.56–2.35
535
(W)
WATT.
Width (mm)
Height (mm)
Depth (mm)
(kg)
790
780
790
780
Dimensions
Net weight
295
550
295
550
242
290
242
290
12
39
12
39
Type
Reverse cycle, Split type
Model
Indoor Unit
Outdoor Unit
Indoor Unit
Outdoor Unit
RAS-13PKVP-E
RAS-13PAVP-E
RAS-16PKVP-E
RAS-16PAVP-E
RAS-13PKVP-ND
RAS-13PAVP-ND
RAS-16PKVP-ND
RAS-16PAVP-ND
Power supply
220–240 V ~50 Hz
220–240 V ~50 Hz
220–230 V ~60 Hz
220–230 V ~60 Hz
Cooling capacity
Heating capacity
Cooling current
Cooling power
Heating current
Heating power
(kW) CAPA.
(kW) CAPA.
3.5
4.0
4.5
5.5
(A)
(W)
(A)
AMP.
0.24–0.22
3.44–3.15
740
0.27–0.25
5.54–5.08
1195
5.97–5.47
1305
780
WATT.
AMP.
30
0.24–0.22
30
35
0.27–0.25
35
3.77–3.46
810
(W)
WATT.
Width (mm)
Height (mm)
Depth (mm)
(kg)
790
780
790
Dimensions
Net weight
295
550
295
550
242
290
242
290
12
40
12
40
Type
Reverse cycle, Split type
Model
Indoor Unit
Outdoor Unit
RAS-18PKVP-E
RAS-18PAVP-E
RAS-18PKVP-ND
RAS-18PAVP-ND
Power supply
220–240 V ~50 Hz
220–230 V ~60 Hz
Cooling capacity
Heating capacity
Cooling current
Cooling power
Heating current
Heating power
(kW) CAPA.
(kW) CAPA.
5.0
6.0
(A)
(W)
(A)
AMP.
0.30–0.28
40
6.68–6.12
1450
6.86–6.29
1500
780
WATT.
AMP.
0.30–0.28
40
(W)
WATT.
Width (mm)
Height (mm)
Depth (mm)
(kg)
790
Dimensions
Net weight
295
550
242
290
12
40
• These specifications are subject to change without notice for the purpose of incorporating technical improvements.
EN
28
The specified air-conditioning performance is based on the data determined under the following conditions.
For cooling For heating
Air inlet temperature °C
Indoor coil assembly Outdoor coil assembly
Air inlet temperature °C
Indoor coil assembly Outdoor coil assembly
Dry bulb
27
Wet bulb
19
Dry bulb
35
Wet bulb
24
Dry bulb
20
Wet bulb
—
Dry bulb
7
Wet bulb
6
29
EN
Information according to EMC Directive 2004/108/EC
(Name of the manufacturer)
(Address, city, country)
TOSHIBA CARRIER CORPORATION
336 Tadehara, Fuji-shi, Shizuoka-ken,
416-8521 Japan
(Name of the Importer / Distributor in EU)
(Address, city, country)
Toshiba Carrier UK Ltd.
Porsham Close, Belliver Industrial Estate,
PLYMOUTH, Devon, PL6 7DB.
United Kingdom
EG44550301
|
Xerox All In One Printer 6115mfp User Manual